MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jsurg.2026.104073

Медицинская библиотека · Journal of surgical education · 2026

"Slow Is Smooth, Smooth Is Fast": Artificial Intelligence-Driven Suturing Simulation for Cardiothoracic Surgical Training.

Wang Sue X, Wang Vivian, Masoumi Shahab, Homaei Ali, Lee Joon Haeng, Kohel Karim, Baioumy Ahmed, Sabe Ashraf, Danesi Tommaso, Hackmann Amy, Aranki Sary, Jaklitsch Michael T, Dias Roger D, Marshall M Blair, Xu Qiuyan, Shin Borami

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To develop and evaluate a suturing simulator using Artificial intelligence (AI)-driven computer vision for objective, high-resolution assessment of technical performance in cardiothoracic surgery, applied to a novel 3D-printed simulator across different levels of surgical expertise.

DESIGN

Prospective study using a novel 3D-printed suturing simulator with targets positioned at multiple depths and angles relevant to cardiothoracic surgery. Participants performed standardized running baseball sutures on 2 planes while procedural videos and post-completion images were recorded. Supervised machine learning-based video tracking (MediaPipe) and classical image processing were used to derive temporal metrics, hand path length, acceleration variability, movement irregularity, and suture uniformity. These metrics were then compared between attending surgeons and trainees.

SETTING

Brigham and Women's Hospital, an academic tertiary care center in Boston, Massachusetts.

PARTICIPANTS

Ten attending cardiac surgeons and 10 surgical trainees.

RESULTS

AI-assisted video analysis differentiated experts from trainees with high precision. Attending cardiac surgeons performed significantly faster than trainees in needle loading (1.9 seconds vs. 2.5 seconds, p < 0.01) and stitch execution (4.6 seconds vs. 6.4 seconds, p < 0.01), resulting in shorter ring completion times (252 seconds vs. 312 seconds, p < 0.02). Attending surgeons also demonstrated superior motion efficiency and less irregular movements during key maneuvers, characterized by reduced overall path length (6,714 vs. 10,154 mm, p = 0.01), lower average acceleration (20 vs. 25 mm/s2, p = 0.01) and reduced vibrational motion patterns (26,786,414 vs. 56,008,703 mm2/s4, p = 0.01). Image analysis confirmed that attending surgeons produced significantly more uniform sutures with lower variability in inter-stitch distances (standard deviation [SD] 1.72 vs. 2.14 mm, p = 0.02; uniformity 68.9% vs. 63.1%, p = 0.03).

CONCLUSIONS

AI-based assessment on an anatomically relevant simulator distinguished experts from novices using granular and mechanistic metrics of suturing skill across AI-segmented motion phases. Experts demonstrated more deliberate, controlled, and smoother movements while completing tasks in less time.

Для цитирования: Wang Sue X, Wang Vivian, Masoumi Shahab, Homaei Ali, Lee Joon Haeng, Kohel Karim, Baioumy Ahmed, Sabe Ashraf, Danesi Tommaso, Hackmann Amy, Aranki Sary, Jaklitsch Michael T, Dias Roger D, Marshall M Blair, Xu Qiuyan, Shin Borami. "Slow Is Smooth, Smooth Is Fast": Artificial Intelligence-Driven Suturing Simulation for Cardiothoracic Surgical Training.. Journal of surgical education. 2026. DOI: 10.1016/j.jsurg.2026.104073.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.