DOI 10.1002/mp.70581

Медицинская библиотека · Medical physics · 2026

Vector-Driven Projection and Backprojection.

Turker Ismail Melik, Yildirim Isa

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Projection and backprojection are fundamental operators in tomographic image reconstruction. Existing approaches-namely pixel-driven (PD), ray-driven (RD), and distance-driven (DD)-are subject to well-known trade-offs among interpolation artifacts, geometric flexibility, and computational cost.

PURPOSE: This study aims to introduce a unified framework that systematically models and resolves the intrinsic limitations of current projection topologies. Within this framework, a novel topology called vector-driven (VD) is proposed to improve geometric flexibility without sacrificing computational efficiency.

METHODS

A three-level hierarchical formulation-comprising topology, algorithm, and implementation-is also developed to isolate the structural origins of artifacts and performance bottlenecks in projection operators. The proposed VD projection and backprojection method represents all tomographic system components as vectors in 3D space and performs non-orthogonal projections that preserve geometric symmetry between forward and backward operations.

RESULTS

Experimental validation was conducted using multiple geometric configurations, and quantitative image quality metrics (SSIM, RMSE, PSNR, NCC, UIQI) were compared against PD, RD, and DD baselines. VD produced artifact-free output across all tested geometries and reached near-perfect image-quality scores matching the leading RD-PD baseline combination. VD attained the shortest wall-clock time in both directions, running about 37% faster than an optimised PD algorithm in forward projection and reaching near parity in backprojection, while remaining 31%-57% faster than De Man's DD and 62%-82% faster than Siddon's RD in both directions. This advantage reflects VD's balanced profile of low arithmetic workload of 13.7-24.0 GFLOP per call (giga floating-point operations), high pipeline efficiency with 3.6-4.4 instructions per cycle (IPC), and low DRAM traffic of about 5 GB read per call.

CONCLUSIONS

VD unifies forward and backward projection within a single vector-based model and, in the configurations tested, performs competitively with established projection topologies in both accuracy and computational cost.

Для цитирования: Turker Ismail Melik, Yildirim Isa. Vector-Driven Projection and Backprojection.. Medical physics. 2026. DOI: 10.1002/mp.70581.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.