"Two-For-One": 4D Cardiac and Pulmonary MR Imaging From a Single Acquisition Using bSTAR.
Клиническое исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Daudé Pierre, Taylor Jordan, Plummer Joseph W, Ramasawmy Rajiv, Tsakirellis Anastasia, Moss Joel, Bandettini W Patricia, Chen Marcus, Campbell-Washburn Adrienne E, Javed Ahsan
Аннотация
PURPOSE: To generate 4D (3D+time) images of both the heart and lungs using a single volumetric radial free-breathing bSSFP dual echo acquisition (bSTAR) with two image reconstructions within a single pipeline deployed inline at 0.55 and 1.5 T.
METHODS: 10 healthy volunteers and 12 patients with cardiomyopathy, lung diseases, or pulmonary hypertension were imaged at 0.55 T. Left-ventricular volumetry was compared to 2D cine images for the cardiac images. Image quality score was measured by two expert readers for cardiac and pulmonary bSTAR images.
RESULTS: Cardiac and pulmonary images were reconstructed inline in 18 min 28 s and 8 min 39 s respectively. Ejection Fraction measurements showed no significant difference (mean bias -0.39%, p > 0.05) between bSTAR and 2D cines. Experts scored whole heart bSTAR images fair-to-good (image quality score of 3.47 ± 0.58) and whole lung bSTAR images as good (image quality score of 3.94 ± 0.85).
CONCLUSION: The ability to assess both cardiac and lung morphology and function in a single scan with parallel image reconstructions will facilitate the evaluation of the cardio-pulmonary interplay.
TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT03331380.
METHODS: 10 healthy volunteers and 12 patients with cardiomyopathy, lung diseases, or pulmonary hypertension were imaged at 0.55 T. Left-ventricular volumetry was compared to 2D cine images for the cardiac images. Image quality score was measured by two expert readers for cardiac and pulmonary bSTAR images.
RESULTS: Cardiac and pulmonary images were reconstructed inline in 18 min 28 s and 8 min 39 s respectively. Ejection Fraction measurements showed no significant difference (mean bias -0.39%, p > 0.05) between bSTAR and 2D cines. Experts scored whole heart bSTAR images fair-to-good (image quality score of 3.47 ± 0.58) and whole lung bSTAR images as good (image quality score of 3.94 ± 0.85).
CONCLUSION: The ability to assess both cardiac and lung morphology and function in a single scan with parallel image reconstructions will facilitate the evaluation of the cardio-pulmonary interplay.
TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT03331380.