MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1123/ijspp.2025-0511

Медицинская библиотека · International journal of sports physiology and performance · 2026

Time to Exhaustion at Traditional Physiological Indicators in Runners: Between-Subject and Between-Day Variability.

Pallarés Jesus G, Valenzuela Pedro L, Martínez-Cava Alejandro, Higuera-Liébana Enrique, Buendía-Romero Ángel, Cervantes Alfonso, Mora-Rodriguez Ricardo

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The maximum oxygen uptake (V˙O2max), respiratory compensation point (RCP), and maximal lactate steady state (MLSS) are indicators used to assess athletes' performance. There is scarce information available on the tolerable duration of exercise (time to exhaustion [TTE]) while running at these physiological indicators. We aimed to analyze the TTE when running at these indicators, as well as to determine their between-subject variability and within-subject reliability.

METHODS

Thirteen male athletes volunteered to participate (V˙O2max=60.2[4.2] mL·kg-1·min-1). Participants V˙O2max, RCP, and MLSS were assessed through treadmill testing, and they performed 2 TTE tests on different occasions at the speed corresponding to each indicator, during which blood lactate, heart rate, and perceptual responses were measured.

RESULTS

TTEs were 03:38 (00:40), 10:58 (02:59), and 56:42 (13:02) mm:ss at the V˙O2max, RCP, and MLSS, respectively. A moderate between-subject variability was observed (coefficient of variation = 18.3%, 27.3%, and 23.0% for V˙O2max, RCP, and MLSS), but no significant associations were found between TTEs and other fitness indicators, such as the speed at which these intensities occurred, nor between TTEs and V˙O2max (all r < .1; P > 0.2). A high within-subject (ie, between-day) reliability was observed for the TTE at all indicators (coefficient of variation of 4.4%, 4.8%, and 6.4% for V˙O2max, RCP, and MLSS, respectively, and intraclass correlation coefficient of .94 and .97, and .90, respectively).

CONCLUSIONS

Given their high within-subject reliability and their independence from other traditional physiological indicators of performance, TTE tests could be used for performance monitoring and for training prescription purposes.

Для цитирования: Pallarés Jesus G, Valenzuela Pedro L, Martínez-Cava Alejandro, Higuera-Liébana Enrique, Buendía-Romero Ángel, Cervantes Alfonso, Mora-Rodriguez Ricardo. Time to Exhaustion at Traditional Physiological Indicators in Runners: Between-Subject and Between-Day Variability.. International journal of sports physiology and performance. 2026. DOI: 10.1123/ijspp.2025-0511.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.