MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1123/ijspp.2025-0382

Медицинская библиотека · International journal of sports physiology and performance · 2026

Validity of Stryd Running Power for Estimating Metabolic Demand During Incline Treadmill Running.

van Rassel Cody R, Gow Scott, Watanabe Takuya, Jaén-Carrillo Diego, MacInnis Martin J

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

PURPOSE: Inertial measurement units, like the shoe-mounted Stryd running power meter, offer an alternative metric to guide endurance training. Despite its utility on level running surfaces, whether Stryd can accurately monitor training intensity for inclined running is unclear.

METHODS

Ten (4 females) trained runners (28 [8] y, 55.9 [9.1] mL/kg/min) performed a Step-Ramp-Step exercise test to estimate the running power at the respiratory compensation point. On a separate visit, participants performed 5-minute running trials at 0%, 2%, 4%, 6%, and 8% inclines in a random order, with speed adjusted to elicit the running power 10% below respiratory compensation point. Metabolic power and mechanical efficiency were calculated for the final minute of each trial.

RESULTS

Metabolic power and oxygen uptake at 6% (1063 [191] W, 3.02 [0.53] L/min) and 8% (1079 [219] W, 3.05 [0.62] L/min) were significantly higher (P < .05 for all comparisons) than at 0% (1037 [191] W, 2.95 [0.53] L/min). Consequently, mechanical efficiency was significantly lower at 6% (21.6% [1.4%]; P = .024) and 8% (21.3% [1.3%]; P = .006) compared with 0% (22.1% [1.3%]). These variables were not different from 0% for the 2% and 4% running trials (P > .05). Ventilation (P = .550), breathing frequency (P = .273), heart rate (P = .924), and rating of perceived exertion (P = .709) were not different across inclines.

CONCLUSIONS

Although Stryd slightly underestimated metabolic power (∼2%-4%) at steeper inclines, running at a fixed Stryd power yielded relatively consistent indications of metabolic demand across incline conditions, suggesting it is a useful metric to guide training during incline treadmill running.

Для цитирования: van Rassel Cody R, Gow Scott, Watanabe Takuya, Jaén-Carrillo Diego, MacInnis Martin J. Validity of Stryd Running Power for Estimating Metabolic Demand During Incline Treadmill Running.. International journal of sports physiology and performance. 2026. DOI: 10.1123/ijspp.2025-0382.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.