A 5000 Fps, 4 Megapixel, Radiation-Tolerant, Wafer-Scale CMOS Image Sensor for the Direct Detection of Electrons and Photons.

Scott Andrew, Bauzà Claus, Bofill-Petit Adrià, Font Albert, Gargallo Mireia, Gifreu Robert, Latif Kamran, Mollà Garcia Armand, Sannino Michele, Turchetta Renato

СтатьяПеревод в очереди

Аннотация

We present the design and characterisation of a 4.2-megapixel, wafer-scale CMOS image sensor, achieving over 5000 frames per second at full resolution. The sensor has a pixel pitch of 58 µm square pixels, thus being as large as a full 200 mm wafer. The sensor is read out on two sides and features column-parallel programmable gain amplifiers (PGAs) as well as analogue-to-digital converters (ADCs). The array has 2052 columns and 2064 rows; 12 rows are read in parallel, so that the total number of ADCs is 24,624. The data is transmitted through 216 sub-LVDS lanes running at 1 Gbps in double data rate (DDR). Besides the row and column control, the sensor generates the necessary voltages and currents on a chip. The programming is performed through a serial-to-parallel interface (SPI). The sensor was optimised for direct detection of electrons, but it can also detect photons. Thus, it could be a good candidate for applications where high speed is needed, such as wavefront sensing.

Для цитирования: Scott Andrew, Bauzà Claus, Bofill-Petit Adrià, Font Albert, Gargallo Mireia, Gifreu Robert, Latif Kamran, Mollà Garcia Armand, Sannino Michele, Turchetta Renato. A 5000 Fps, 4 Megapixel, Radiation-Tolerant, Wafer-Scale CMOS Image Sensor for the Direct Detection of Electrons and Photons.. Sensors (Basel, Switzerland). 2026. DOI: 10.3390/s26020370.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.