MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jfmk10020136

Медицинская библиотека · Journal of functional morphology and kinesiology · 2025

Reliability of Muscle Oxygen Saturation for Evaluating Exercise Intensity and Knee Joint Load Indicators.

Vasquez-Bonilla Aldo A, Yáñez-Sepúlveda Rodrigo, Monsalves-Álvarez Matías, Tuesta Marcelo, Duclos-Bastías Daniel, Cortés-Roco Guillermo, Olivares-Arancibia Jorge, Guzmán-Muñoz Eduardo, López-Gil José Francisco

СтатьяПеревод в очереди

Аннотация

Objectives

This study aimed to evaluate the reliability of muscle oxygen saturation (SmO2) and its correlation with variables from an inertial measurement unit (IMU) sensor placed on the knee at different exercise intensities.

Methods

Fourteen university athletes participated in the study. Incremental ergospirometry was performed to exhaustion to calculate V'O2max, determine training zones, heart rate, and workload using the IMU, and analyze muscle metabolism by SmO2.

Results

The analysis revealed significant differences between moderate-to-high-intensity zones (80-89% vs. 50-69%, Δ = 27% of SmO2; p < 0.001) and high-intensity zones (90-100% vs. 50-79%, Δ = 35% of SmO2; p < 0.001). SmO2 values showed moderate reliability at moderate exercise intensities (e.g., ICC 0.744 at 50%) and high variability at higher intensities, with ICC values around 0.577-0.594, and CV% increasing up to 77.7% at 100% intensity, indicating decreasing consistency as exercise intensity increases. SmO2 significantly decreases with increasing angular velocity (β = -13.9, p < 0.001), while knee joint load only shows significant correlations with SmO2 in the moderate-to-high-intensity zones (r = 0.569, p = 0.004) and high-intensity zones (r = 0.455, p = 0.012).

Conclusions

SmO2 is a key predictor of performance during maximal incremental exercise, particularly in high-intensity zones. Moreover, SmO2 has the potential to serve as a physiological marker of the internal load on the muscles surrounding the knee during exercise. The SmO2 decrease could depend on the angular velocity and impact of the exposed knee during running.

Для цитирования: Vasquez-Bonilla Aldo A, Yáñez-Sepúlveda Rodrigo, Monsalves-Álvarez Matías, Tuesta Marcelo, Duclos-Bastías Daniel, Cortés-Roco Guillermo, Olivares-Arancibia Jorge, Guzmán-Muñoz Eduardo, López-Gil José Francisco. Reliability of Muscle Oxygen Saturation for Evaluating Exercise Intensity and Knee Joint Load Indicators.. Journal of functional morphology and kinesiology. 2025. DOI: 10.3390/jfmk10020136.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.