m+Medelevator.RU
← Поиск публикаций
Physics in medicine and biology · 2025

Computationally efficient collimator-detector response compensation in high energy SPECT using 1D convolutions and rotations.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Polson Lucas A, Esquinas Pedro, Kurkowska Sara, Li Chenguang, Sheikhzadeh Peyman, Abbassi Mehrshad, Farzanehfar Saeed, Mirabedian Seyyede, Uribe Carlos, Rahmim Arman

Аннотация

Objective. Modeling of the collimator-detector response (CDR) in single photon emission computed tomography (SPECT) reconstruction enables improved resolution and accuracy, and is thus important for quantitative imaging applications such as dosimetry. The implementation of CDR modeling, however, can become a computational bottleneck when there are substantial components of septal penetration and scatter in the acquired data, since a direct convolution-based approach requires large 2D kernels. This work proposes a 1D convolution and rotation-based CDR model that reduces reconstruction times but maintains consistency with models that employ 2D convolutions. To enable open-source development and use of these models in image reconstruction, we release a SPECTPSFToolbox repository for the PyTomography project on GitHub.Approach. A 1D/rotation-based CDR model was formulated and subsequently fit to Monte Carlo (MC) point source data representative of177Lu,131I, and225Ac imaging. Computation times of (i) the proposed 1D/rotation-based model and (ii) a traditional model that uses 2D convolutions were compared for typical SPECT matrix sizes. Both CDR models were then used in the reconstruction of MC, physical phantom, and patient data; the models were compared by quantifying total counts in hot regions of interest (ROIs) and activity contrast between hot ROIs and background regions.Results. For typical matrix sizes in SPECT reconstruction, application of the 1D/rotation-based model provides a two-fold computational speed-up over the 2D model when running on GPU. Only small differences between the 1D/rotation-based and 2D models (order of 1%) were obtained for count and contrast quantification in select ROIs.Significance. A technique for CDR modeling in SPECT was proposed that (i) significantly speeds up reconstruction times, and (ii) yields nearly identical reconstructions to traditional 2D convolution based CDR techniques. The released toolbox will permit open-source development of similar models for different isotopes and collimators.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты