DOI 10.1097/nan.0000000000000563

Медицинская библиотека · Journal of infusion nursing : the official publication of the Infusion Nurses Society · 2024

Usability of Light-Linking Technology for Infusion Line Identification: A Simulation Study With ICU Nurses.

Huffman Carolyn, Butcher Wendy, Gonzales Cliff, Hampton Kerrin, Munn Lindsay, Saunders Ian, Russell Greg

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Critical care nurses are faced with increasing task loads due to increasing patient complexity. In addition to this complexity, most critical care patients have a maze of infusion and monitoring lines that must be navigated when administering medications. Task load is escalated when a nurse must identify an injection port and administer a medication rapidly. This study tested a commercially available light-linking infusion line identification device. Researchers compared standard labeling practices to the light-linking technology on time to injection, error rate, usability, and task load. Forty-seven intensive care nurses completed 188 critical care simulations using a randomized cross-over design. Simulations were carried out in both daylight and low-light conditions. The light-linking technology reduced overall time to injection compared to standard labeling practices and demonstrated a significant decrease in time to injection in low-light settings, greater perceived usability, and lower perceived task load. Injection error rate could not be adequately assessed, but 6 of 8 errors were committed in low-light conditions.

Для цитирования: Huffman Carolyn, Butcher Wendy, Gonzales Cliff, Hampton Kerrin, Munn Lindsay, Saunders Ian, Russell Greg. Usability of Light-Linking Technology for Infusion Line Identification: A Simulation Study With ICU Nurses.. Journal of infusion nursing : the official publication of the Infusion Nurses Society. 2024. DOI: 10.1097/nan.0000000000000563.

Предметные рубрики MeSH