m+Medelevator.RU
← Поиск публикаций
International journal of cardiology · 2010

Local persistent hypercoagulability after sirolimus-eluting stent implantation in patients with stable angina.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yamaguchi Koji, Wakatsuki Tetsuzo, Niki Toshiyuki, Kusunose Kenya, Koshiba Kunihiko, Yagi Shusuke, Taketani Yoshio, Iwase Takashi, Tomita Noriko, Yamada Hirotsugu, Soeki Takeshi, Akaike Masashi, Sata Masataka

Аннотация

BACKGROUND: Late stent thrombosis (LST) after sirolimus-eluting stent (SES) implantation has been demonstrated previously. Although incomplete neointimal coverage after SES implantation has been reported, local long-term hypercoagulability remains unknown.

METHODS: We evaluated the local persistent coagulative response in eighty-three consecutive patients with stable angina, treated with either SES (n=51) or BMS (n=32) implantation for isolated de novo left anterior descending (LAD) stenosis. We measured prothrombin fragment F1+2 (frF1+2) and D-dimer levels sampled in the coronary sinus (CS) and sinus of Valsalva (V). The transcardiac gradient (Δ) was defined as the CS level minus V level.

RESULTS: The ΔfrF1 + 2 and ΔD-dimer were significantly greater in the SES group than in the BMS group (0.50 ± 0.35 vs -0.14 ± 0.15 nmol/l, p=0.009 and 0.24 ± 0.21 vs -0.05 ± 0.16 μg/ml, p=0.041, respectively). We selected the hypocoagulative [ΔfrF1 + 2<0.15 (mean value-SD) nmol/l, n=21] and hypercoagulative [ΔfrF1 + 2>0.85 (mean value+SD) nmol/l, n=14] groups out of the SES patients. Multivariate analysis was performed to identify independent predictors of local hypercoagulability. Total SES length was the only independent predictor of local hypercoagulability. There was a significant positive correlation between the ΔfrF1 + 2 and total stent length in the SES group (r=0.57, p<0.05).

CONCLUSIONS: An increased local coagulative response was observed in the convalescent phase after SES implantation as compared to BMS. Careful long-term follow-up of patients after longer SES implantation is recommended in order to avoid LST.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты