The Effect of Water Dousing on Heat Strain and Performance During Endurance Running in the Heat.
Аннотация
OBJECTIVES
Assess the effect of water dousing on heat strain and performance during self- and fixed-paced exercise in the heat.
DESIGN
Crossover, block-randomized controlled trial.
METHODS
Thirteen trained runners completed a 10-km time trial (TT) and 60-minute fixed-pace run (60% velocity of V˙O2max) in a 30.4 °C, 47.4% relative humidity environment using either water dousing (DOUSE) or no dousing (CON).
RESULTS
Ten-kilometer TT performance was faster in DOUSE compared to CON (44:11 [40:48, 47:34] vs 44:38 [41:21, 47:56] min:s; P = .033). Change in core temperature (Tc) was not different between groups during the TT (+0.02 [-0.04, 0.07] °C in DOUSE; P = .853) or fixed-pace run (+0.02 [-0.15, 0.18] °C; P = .848). Change in mean skin temperature was lower in DOUSE during the TT (-1.80 [-2.15, -1.46] °C; P < .001) and fixed-pace run (-1.38 [-1.81, -0.96] °C; P < .001). Heart rate was lower for DOUSE during the fixed-pace run (-3.5 [-6.8, -0.2] beats/min; P = .041) but not during the TT (-0.2 [-2.5, 2.1] beats/min; P = .853). Thermal sensation was lower for DOUSE during the TT (-49.3 [-72.1, -26.1] mm; P < .001) and fixed-pace run (-44.7 [-59.7, -29.6] mm; P < .001). Rating of perceived exertion was not different between groups for the TT (-0.2 [-0.7, 0.3]; P = .390) or fixed-pace run (-0.2 [-0.8, 0.4]; P = .480). Sweat rate was lower for DOUSE for the TT (-0.37 [-0.53, -0.22] L/h; P < .001) and fixed-pace run (-0.37 [-0.48, -0.26] L/h; P < .001).
CONCLUSION
Water dousing improves 10-km TT performance in the heat but does not affect Tc. The positive change in thermal perception (via lower skin temperature) during the TT likely drives this benefit.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.