Tanaffos · 2015
Assessment of Occupational Exposure to Dust and Crystalline Silica in Foundries.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Omidianidost Ali, Ghasemkhani Mehdi, Azari Mansour R, Golbabaei Farideh
Аннотация
BACKGROUND: The term "crystalline silica" refers to crystallized form of SiO2 and quartz, as the most abundant compound on the earth's crust; it is capable of causing silicosis and lung cancer upon inhaling large doses in the course of occupational exposure. The aim of this study was to assess occupational exposure to dust and crystalline silica in foundries in Pakdasht, Iran.
MATERIALS AND METHODS: In this study, airborne dust samples were collected on PVC filters (37 mm diameter, 0.8 mm pore size), by using a sampling pump and open face cyclone at a flow rate of 2.2 l/min for a maximum volume of 800 liters. For determining crystalline silica spectrometry was used according to the National Institute of Occupational Safety and Health (NIOSH) method No. 7601 for analysis of samples.
RESULTS: Results showed that crystalline silica concentration was higher than NIOSH and the American Conference of Government Industrial Hygienist (ACGIH) allowed extent (0.025 mg/m(3)). Concentration of crystalline silica was 0.02-0.1 mg/m(3). Total dust concentration average was higher than the allowed extent by Permissible Exposure Limit (PEL) of the Occupational Safety and Health Administration (OSHA).
CONCLUSION: It is essential to take necessary measures to control crystalline silica dust regarding the fact that 50% of workers are exposed to higher than the allowed extent.
MATERIALS AND METHODS: In this study, airborne dust samples were collected on PVC filters (37 mm diameter, 0.8 mm pore size), by using a sampling pump and open face cyclone at a flow rate of 2.2 l/min for a maximum volume of 800 liters. For determining crystalline silica spectrometry was used according to the National Institute of Occupational Safety and Health (NIOSH) method No. 7601 for analysis of samples.
RESULTS: Results showed that crystalline silica concentration was higher than NIOSH and the American Conference of Government Industrial Hygienist (ACGIH) allowed extent (0.025 mg/m(3)). Concentration of crystalline silica was 0.02-0.1 mg/m(3). Total dust concentration average was higher than the allowed extent by Permissible Exposure Limit (PEL) of the Occupational Safety and Health Administration (OSHA).
CONCLUSION: It is essential to take necessary measures to control crystalline silica dust regarding the fact that 50% of workers are exposed to higher than the allowed extent.