MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/hrt.2010.199042

Медицинская библиотека · Heart (British Cardiac Society) · 2010

Diesel exhaust inhalation does not affect heart rhythm or heart rate variability.

Mills Nicholas L, Finlayson Alexander E, Gonzalez Manuel C, Törnqvist Håkan, Barath Stefan, Vink Elen, Goudie Colin, Langrish Jeremy P, Söderberg Stefan, Boon Nicholas A, Fox Keith A A, Donaldson Ken, Sandström Thomas, Blomberg Anders, Newby David E

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Exposure to air pollution is associated with increases in cardiovascular morbidity and mortality. This study was undertaken to determine the effect of diesel exhaust inhalation on heart rhythm and heart rate variability in healthy volunteers and patients with coronary heart disease.

DESIGN AND

SETTING

Double-blind randomised crossover studies in a university teaching hospital.

PATIENTS: 32 healthy non-smoking volunteers and 20 patients with prior myocardial infarction.

INTERVENTIONS: All 52 subjects were exposed for 1 h to dilute diesel exhaust (particle concentration 300 μg/m³) or filtered air.

MAIN OUTCOME MEASURES: Heart rhythm and heart rate variability were monitored during and for 24 h after the exposure using continuous ambulatory electrocardiography and assessed using standard time and frequency domain analysis.

RESULTS

No significant arrhythmias occurred during or following exposures. Patients with coronary heart disease had reduced autonomic function in comparison to healthy volunteers, with reduced standard deviations of the NN interval (SDNN, p < 0.001) and triangular index (p < 0.001). Diesel exhaust did not affect heart rate variability compared with filtered air (p > 0.05 for all) in healthy volunteers (SDNN 101 ± 6 vs 91 ± 6, triangular index 20 ± 1 vs 21 ± 1) or patients with coronary heart disease (SDNN 47 ± 5 vs 38 ± 4, triangular index 8 ± 1 vs 7 ± 1).

CONCLUSIONS

Brief exposure to dilute diesel exhaust does not alter heart rhythm or heart rate variability in healthy volunteers or well-treated patients with stable coronary heart disease. Autonomic dysfunction does not appear to be a dominant mechanism that can explain the observed excess in cardiovascular events following exposure to combustion-derived air pollution.

Для цитирования: Mills Nicholas L, Finlayson Alexander E, Gonzalez Manuel C, Törnqvist Håkan, Barath Stefan, Vink Elen, Goudie Colin, Langrish Jeremy P, Söderberg Stefan, Boon Nicholas A, Fox Keith A A, Donaldson Ken, Sandström Thomas, Blomberg Anders, Newby David E. Diesel exhaust inhalation does not affect heart rhythm or heart rate variability.. Heart (British Cardiac Society). 2010. DOI: 10.1136/hrt.2010.199042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.