MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/jips.jips_570_23

Медицинская библиотека · Journal of Indian Prosthodontic Society · 2024

Assessment of different shielding materials for radiation therapy of maxillofacial tumors - An in vitro study.

Mohamed K Kasim, Srinivas K Satish, Seenivasan Madhankumar, Babu Annapoorani

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

AIM: Since the advent of radiotherapy, the success rate of head and neck cancer treatment has increased significantly. However, when the tissue tolerance level is exceeded, unnecessary and uncontrolled exposure to radiation is considered detrimental. Such problems remain difficult to prevent and manage. The aim of the study to evaluate and compare the degree of attenuation of therapeutic radiation using four different radiation shielding materials of varying thickness.

STUDY SETTING AND

DESIGN

In vitro experimental study.

MATERIALS AND

METHODS

The samples were divided into four groups based on the different radiation shielding materials of thickness 3mm and 5mm. The materials are Lead (Pb), Silver-tin alloy (Ag-Sn) with Polyvinylsiloxane (PVS), Polymethylmethacrylate (PMMA) with Barium sulphate (BaSO4), and a combination of Ag-Sn with PVS and PMMA with BaSO4 which was exposed to radiation. The radiation dose measurements were recorded and the radiation attenuation properties of the shielding materials were evaluated. Among all of the shielding materials the most efficient material under consideration is determined.

STATISTICAL ANALYSIS USED: One-way ANOVA followed by post hoc test was used to compare the means of all four groups.

RESULTS

A statistically significant difference between groups was found by a one-way ANOVA with a P = 0.001. In the post hoc test, statistically significant findings were obtained with a P = 0.05 when comparing the variation values of 3mm and 5mm thickness between each group and other groups.

CONCLUSION

The shielding materials results in significant reductions in radiation dosage. It was concluded that the combinations of Ag-Sn alloy with PVS, and PMMA with BaSO4 of thickness 5 mm had a good shielding effect.

Для цитирования: Mohamed K Kasim, Srinivas K Satish, Seenivasan Madhankumar, Babu Annapoorani. Assessment of different shielding materials for radiation therapy of maxillofacial tumors - An in vitro study.. Journal of Indian Prosthodontic Society. 2024. DOI: 10.4103/jips.jips_570_23.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.