MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/1361-6498/acb82b

Медицинская библиотека · Journal of radiological protection : official journal of the Society for Radiological Protection · 2023

Cardiologist's exposure to radiation in cath lab measured with InstadoseTMdosimeter.

Moreira Antônio Carlos, da Silva Branco Amanda Juliene, Khoury Helen Jamil, Pires Silvio Ricardo, Pereira Barbosa Adriano Henrique, Bitelli Medeiros Regina

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

complex fluoroscopy-guided interventional procedures in cardiology are known to result in higher radiation doses for patients and staff.

PURPOSE: to estimate the equivalent dose received in different regions of the cardiologist's body in catheterism (CATH) and percutaneous coronary intervention (PCI) procedures, as well as to evaluate the effectiveness of monitoring the doses in the catheritization laboratory (cath lab) using a direct ion storage dosimeter.

MATERIALS AND

METHODS

the InstadoseTMand the thermoluminescent dosimeters (TLD-100) were fixed simultaneously in the following regions of the cardiologist's body: near the eyes (left and right), the trunk region (over the lead apron) and the left ankle. Occupational doses were recorded during 86 procedures (60% CATH).

RESULTS

catheterization procedures showed third quartile dose values near to the left eye region equal to 0.10 mSv (TLD-100) and 0.12 (InstadoseTM) and for intervention 0.15 mSv (TLD-100 and InstadoseTM). The doses measured in the trunk region, over the lead apron, were about 13% higher for catheterization procedures and 20% higher for intervention procedures compared to left eye region measurements. The Wilcoxon-Mann-Whitney test was applied for unpaired data for all body regions, comparing the data obtained between the TLD-100 and InstadoseTMdosimeters. For CATH and PCI, the responses of the TLD-100 and InstadoseTMdosimeters are considered equal for all analysed regions (p> 0.05) with the exception of the right eye region.

CONCLUSION

the InstadoseTMpassive dosimeter can be useful as a complementary assessment in the monitoring of a cardiologist's personal occupational doses in the cath lab.

Для цитирования: Moreira Antônio Carlos, da Silva Branco Amanda Juliene, Khoury Helen Jamil, Pires Silvio Ricardo, Pereira Barbosa Adriano Henrique, Bitelli Medeiros Regina. Cardiologist's exposure to radiation in cath lab measured with InstadoseTMdosimeter.. Journal of radiological protection : official journal of the Society for Radiological Protection. 2023. DOI: 10.1088/1361-6498/acb82b.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.