MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1259/bjr.20200754

Медицинская библиотека · The British journal of radiology · 2021

First experience of efficacy and radiation exposure in 320-detector row CT fluoroscopy-guided interventions.

Yamamoto Shota, Matsumoto Tomohiro, Suda Satoshi, Tomita Kosuke, Kamei Shunsuke, Hashida Kazunobu, Imai Yutaka, Endo Kazuyuki, Murakami Katsuki, Hasebe Terumitsu

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

We investigated the efficacy and exposure to radiation in 320-detector row computed tomography fluoroscopy-guided (CTF-guided) interventions.

METHODS

We analysed 231 320-detector row CTF-guided interventions (207 patients over 2 years and 6 months) in terms of technical success rates, clinical success rates, complications, scanner settings, overall radiation doses (dose-length product, mGy*cm), patient doses of peri-interventional CT series, and interventional CT (including CTF), as a retrospective cohort study. The relationships between patient radiation dose and interventional factors were assessed using multivariate analysis.

RESULTS

Overall technical success rate was 98.7% (228/231). The technical success rates of biopsies, drainages, and aspirations were 98.7% (154/156), 98.5% (66/67), and 100% (8/8), respectively. The clinical success rate of biopsies was 93.5% (146/156). All three major complications occurred in chest biopsies. The median total radiation dose was 522.4 (393.4-819.8) mGy*cm. Of the total radiation dose, 87% was applied during the pre- and post-interventional CT series. Post-interventional CT accounted for 24.4% of the total radiation dose. Only 11.4% of the dose was applied by CTF-guided intervention. Multilinear regression demonstrated that male sex, body mass index, drainage, intervention time, and helical scan as post-interventional CT were significantly associated with higher dose.

CONCLUSION

The 320-detector row CTF interventions achieved a high success rate. Dose reduction in post-interventional CT provides patient dose reduction without decreasing the technical success rates.

ADVANCES IN KNOWLEDGE: This is the first study on the relationship between various interventional outcomes and patient exposure to radiation in 320-detector row CTF-guided interventions, suggesting a new perspective on dose reduction.

Для цитирования: Yamamoto Shota, Matsumoto Tomohiro, Suda Satoshi, Tomita Kosuke, Kamei Shunsuke, Hashida Kazunobu, Imai Yutaka, Endo Kazuyuki, Murakami Katsuki, Hasebe Terumitsu. First experience of efficacy and radiation exposure in 320-detector row CT fluoroscopy-guided interventions.. The British journal of radiology. 2021. DOI: 10.1259/bjr.20200754.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.