MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00270-020-02461-1

Медицинская библиотека · Cardiovascular and interventional radiology · 2020

Influence of Interventionists' Experience on Radiation Exposure of Patients Who Underwent Prostate Artery Embolization: 4-Year Results from a Retrospective, Single-Center Study.

Kriechenbauer Bernadette Maria Theresia, Franiel Tobias, Bürckenmeyer Florian, Aschenbach René, Diamantis Ioannis, Malouhi Amer, Steiniger Beatrice, Teichgräber Ulf

СтатьяПеревод в очереди

Аннотация

PURPOSE: To assess radiation exposure in men undergoing prostate artery embolization (PAE) for the treatment for symptomatic, benign prostatic hyperplasia depending on growing experience of interventional radiologists over a 4-year period.

METHODS

A total of 250 consecutive patients underwent PAE at a single center. Data on radiation exposure [dose area product (DAP), effective dose (ED), entrance skin dose (ESD), and fluoroscopy time (FT)] were retrospectively evaluated. Primary outcomes of interest were patient radiation exposure in five consecutive groups of 50 patients each and Pearson correlation with the number of patients treated.

RESULTS

Median DAP, ED, and ESD during prostate artery embolization were significantly higher in the first compared to the second 50 patients (56 298 µGym2 vs. 24 709 µGym2, p < 0.001, 146.4 mSv vs. 64.2 mSv, p < 0.001, and 5.1 Gy vs. 2.4 Gy, p < 0.001, respectively). The following consecutive groups did not differ significantly from the respective preceding group in terms of DAP, ED, and ESD. Number of digital subtraction angiography series, FT, and procedure time decreased with increasing operator experience (Pearson's r = - 0.240, p < 0.001, r = - 0.269, p < 0.001, and r = - 0.504, p < 0.001, respectively). Bilateral prostate artery embolization was associated with less ESD and shorter FT than unilateral embolization (median 2.5 vs. 3.5 Gy, p = 0.02, and 26 min vs. 42 min, p < 0.001, respectively).

CONCLUSION

Exposure to radiation in men who underwent PAE decreased with growing operator experience and decreasing complexity of procedures.

Для цитирования: Kriechenbauer Bernadette Maria Theresia, Franiel Tobias, Bürckenmeyer Florian, Aschenbach René, Diamantis Ioannis, Malouhi Amer, Steiniger Beatrice, Teichgräber Ulf. Influence of Interventionists' Experience on Radiation Exposure of Patients Who Underwent Prostate Artery Embolization: 4-Year Results from a Retrospective, Single-Center Study.. Cardiovascular and interventional radiology. 2020. DOI: 10.1007/s00270-020-02461-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.