MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ccm.0000000000002451

Медицинская библиотека · Critical care medicine · 2017

Ultrasound as a Screening Tool for Central Venous Catheter Positioning and Exclusion of Pneumothorax.

Amir Rabia, Knio Ziyad O, Mahmood Feroze, Oren-Grinberg Achikam, Leibowitz Akiva, Bose Ruma, Shaefi Shahzad, Mitchell John D, Ahmed Muneeb, Bardia Amit, Talmor Daniel, Matyal Robina

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Although real-time ultrasound guidance during central venous catheter insertion has become a standard of care, postinsertion chest radiograph remains the gold standard to confirm central venous catheter tip position and rule out associated lung complications like pneumothorax. We hypothesize that a combination of transthoracic echocardiography and lung ultrasound is noninferior to chest radiograph when used to accurately assess central venous catheter positioning and screen for pneumothorax.

SETTING

All operating rooms and surgical and trauma ICUs at the institution.

DESIGN

Single-center, prospective noninferiority study.

PATIENTS: Patients receiving ultrasound-guided subclavian or internal jugular central venous catheters.

INTERVENTIONS: During ultrasound-guided central venous catheter placement, correct positioning of central venous catheter was accomplished by real-time visualization of the guide wire and positive right atrial swirl sign using the subcostal four-chamber view. After insertion, pneumothorax was ruled out by the presence of lung sliding and seashore sign on M-mode.

MEASUREMENTS AND MAIN

RESULTS

Data analysis was done for 137 patients. Chest radiograph ruled out pneumothorax in 137 of 137 patients (100%). Lung ultrasound was performed in 123 of 137 patients and successfully screened for pneumothorax in 123 of 123 (100%). Chest radiograph approximated accurate catheter tip position in 136 of 137 patients (99.3%). Adequate subcostal four-chamber views could not be obtained in 13 patients. Accurate positioning of central venous catheter with ultrasound was then confirmed in 121 of 124 patients (97.6%) as described previously.

CONCLUSIONS

Transthoracic echocardiography and lung ultrasound are noninferior to chest x-ray for screening of pneumothorax and accurate central venous catheter positioning. Thus, the point of care use of ultrasound can reduce central venous catheter insertion to use time, exposure to radiation, and improve patient safety.

Для цитирования: Amir Rabia, Knio Ziyad O, Mahmood Feroze, Oren-Grinberg Achikam, Leibowitz Akiva, Bose Ruma, Shaefi Shahzad, Mitchell John D, Ahmed Muneeb, Bardia Amit, Talmor Daniel, Matyal Robina. Ultrasound as a Screening Tool for Central Venous Catheter Positioning and Exclusion of Pneumothorax.. Critical care medicine. 2017. DOI: 10.1097/ccm.0000000000002451.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.