Graser Anno, Melzer Anja, Lindner Evelyn, Nagel Dorothea, Herrmann Karin, Stieber Petra, Schirra Jörg, Mansmann Ulrich, Reiser Maximilian F, Göke Burkhard, Kolligs Frank T
Аннотация
BACKGROUND & AIMS: Colonoscopy is the preferred screening test for colorectal neoplasia; the fecal occult blood test (FOBT) detects neoplasias with low levels of sensitivity. Computed tomographic colonography detects neoplasias with high levels of sensitivity but involves exposure to radiation. We investigated whether magnetic resonance colonography (MRC) can be used to screen for colorectal adenomas and cancers.
METHODS: We analyzed data from 286 asymptomatic adults (40-82 years old) who underwent 3 Tesla MRC and colonoscopic examinations on the same day. FOBT was performed before bowel preparation. Colonoscopists were initially blinded to the findings on MRC and unblinded after withdrawal from the respective segments. Sensitivities for adenoma and per-patient sensitivities and specificities were calculated based on the unblinded results of colonoscopy.
RESULTS: We detected 133 adenomas and 2 cancers in 86 patients; 37 adenomas were ≥6 mm, and 20 adenomas were advanced. Sensitivities of MRC and colonoscopy for adenomas ≥6 mm were 78.4% (95% confidence interval [CI], 61.8-90.2) and 97.3% (95% CI, 85.8-99.9); for advanced adenomas these values were 75% (95% CI, 50.9-91.3) and 100% (95% CI, 83.2-100.0), respectively. MRC identified 87.1% (95% CI, 70.2-96.4), colonoscopy 96.8% (95% CI, 83.3-99.9), and FOBT 10.0% (95% CI, 2.1-26.5) of individuals with adenomas ≥6 mm and 83.8% (95% CI, 58.6-96.4), 100% (95% CI, 81.5-100.0), and 17.6% (95% CI, 3.8-43.4) of individuals with advanced neoplasia. Specificities of MRC, colonoscopy, and FOBT for individuals with adenomas ≥6 mm were 95.3% (95% CI, 91.9-97.5), 96.9% (95% CI, 93.9-98.6), and 91.8% (95% CI, 87.6-94.9), respectively.
CONCLUSIONS: 3 Tesla MRC detects colorectal adenomas ≥6 mm and advanced neoplasia with high levels of sensitivity and specificity. Although MRC detects colorectal neoplasia with lower levels of sensitivity than colonoscopy, it strongly outperforms one-time FOBT.
METHODS: We analyzed data from 286 asymptomatic adults (40-82 years old) who underwent 3 Tesla MRC and colonoscopic examinations on the same day. FOBT was performed before bowel preparation. Colonoscopists were initially blinded to the findings on MRC and unblinded after withdrawal from the respective segments. Sensitivities for adenoma and per-patient sensitivities and specificities were calculated based on the unblinded results of colonoscopy.
RESULTS: We detected 133 adenomas and 2 cancers in 86 patients; 37 adenomas were ≥6 mm, and 20 adenomas were advanced. Sensitivities of MRC and colonoscopy for adenomas ≥6 mm were 78.4% (95% confidence interval [CI], 61.8-90.2) and 97.3% (95% CI, 85.8-99.9); for advanced adenomas these values were 75% (95% CI, 50.9-91.3) and 100% (95% CI, 83.2-100.0), respectively. MRC identified 87.1% (95% CI, 70.2-96.4), colonoscopy 96.8% (95% CI, 83.3-99.9), and FOBT 10.0% (95% CI, 2.1-26.5) of individuals with adenomas ≥6 mm and 83.8% (95% CI, 58.6-96.4), 100% (95% CI, 81.5-100.0), and 17.6% (95% CI, 3.8-43.4) of individuals with advanced neoplasia. Specificities of MRC, colonoscopy, and FOBT for individuals with adenomas ≥6 mm were 95.3% (95% CI, 91.9-97.5), 96.9% (95% CI, 93.9-98.6), and 91.8% (95% CI, 87.6-94.9), respectively.
CONCLUSIONS: 3 Tesla MRC detects colorectal adenomas ≥6 mm and advanced neoplasia with high levels of sensitivity and specificity. Although MRC detects colorectal neoplasia with lower levels of sensitivity than colonoscopy, it strongly outperforms one-time FOBT.
Предметные рубрики MeSH
AdenocarcinomaAdenomaAdultAge DistributionAgedAged, 80 and overCohort StudiesColonography, Computed TomographicColonoscopyColorectal NeoplasmsFemaleGermanyHumansIncidenceMagnetic Resonance ImagingMaleMass ScreeningMiddle AgedOccult BloodSensitivity and SpecificitySeverity of Illness IndexSex Distribution