MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijrobp.2009.10.058

Медицинская библиотека · International journal of radiation oncology, biology, physics · 2010

Development and validation of a heart atlas to study cardiac exposure to radiation following treatment for breast cancer.

Feng Mary, Moran Jean M, Koelling Todd, Chughtai Aamer, Chan June L, Freedman Laura, Hayman James A, Jagsi Reshma, Jolly Shruti, Larouere Janice, Soriano Julie, Marsh Robin, Pierce Lori J

СтатьяПоддержка NIH: внешняя программаВалидационное исследованиеПеревод в очереди

Аннотация

PURPOSE: Cardiac toxicity is an important sequela of breast radiotherapy. However, the relationship between dose to cardiac structures and subsequent toxicity has not been well defined, partially due to variations in substructure delineation, which can lead to inconsistent dose reporting and the failure to detect potential correlations. Here we have developed a heart atlas and evaluated its effect on contour accuracy and concordance.

METHODS AND MATERIALS: A detailed cardiac computed tomography scan atlas was developed jointly by cardiology, cardiac radiology, and radiation oncology. Seven radiation oncologists were recruited to delineate the whole heart, left main and left anterior descending interventricular branches, and right coronary arteries on four cases before and after studying the atlas. Contour accuracy was assessed by percent overlap with gold standard atlas volumes. The concordance index was also calculated. Standard radiation fields were applied. Doses to observer-contoured cardiac structures were calculated and compared with gold standard contour doses. Pre- and post-atlas values were analyzed using a paired t test.

RESULTS

The cardiac atlas significantly improved contour accuracy and concordance. Percent overlap and concordance index of observer-contoured cardiac and gold standard volumes were 2.3-fold improved for all structures (p < 0.002). After application of the atlas, reported mean doses to the whole heart, left main artery, left anterior descending interventricular branch, and right coronary artery were within 0.1, 0.9, 2.6, and 0.6 Gy, respectively, of gold standard doses.

CONCLUSIONS

This validated University of Michigan cardiac atlas may serve as a useful tool in future studies assessing cardiac toxicity and in clinical trials which include dose volume constraints to the heart.

Для цитирования: Feng Mary, Moran Jean M, Koelling Todd, Chughtai Aamer, Chan June L, Freedman Laura, Hayman James A, Jagsi Reshma, Jolly Shruti, Larouere Janice, Soriano Julie, Marsh Robin, Pierce Lori J. Development and validation of a heart atlas to study cardiac exposure to radiation following treatment for breast cancer.. International journal of radiation oncology, biology, physics. 2010. DOI: 10.1016/j.ijrobp.2009.10.058.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.