DOI 10.1016/j.rmcr.2017.02.002
A case of mixed dust pneumoconiosis with desquamative interstitial pneumonia-like reaction in an aluminum welder.
Аннотация
A 60-year-old man presented with an 18-month history of gradually worsening cough and a 12-month history of dyspnea on exertion. High-resolution computed tomography showed bilateral uniform ground grass opacity in the lower lung fields, partially resolved by smoking cessation. A tentative diagnosis of desquamative interstitial pneumonia (DIP) was made. Video-assisted thoracic surgery was performed and pathological analysis showed peribronchiolar fibrosis with intra-alveolar macrophage infiltration. Elemental analysis detected aluminum and iron in the upper lobe and only iron in the lower lobe. Thus, a definitive diagnosis of mixed dust pneumoconiosis with DIP-like reaction was made. DIP-like reaction is known to be a reactive change caused by exposure to tobacco smoke as well as by inhalation of inorganic particles. Obtaining a detailed medical history including occupational and environmental risk factors is important to distinguish cases of DIP-like reaction due to exposure to inorganic particles from the usual cases related to smoking, and thus provide suitable treatment.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.