MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/bf03040419

Медицинская библиотека · Wiener klinische Wochenschrift · 2004

Quantification of recent smoking behaviour using proton transfer reaction-mass spectrometry (PTR-MS).

Lirk Philipp, Bodrogi Florian, Deibl Martina, Kähler Christian M, Colvin Joshua, Moser Berthold, Pinggera Germar, Raifer Hartmann, Rieder Josef, Schobersberger Wolfgang

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Smoking is the most important single risk factor in current public health. Surveillance of exposure to tobacco smoke may be accomplished using environmental monitoring or in-vivo tests for smoking biomarkers. Acetonitrile exhaled in human breath has been described as a potential marker mirroring recent smoking behavior. The aim of this study was to determine exhaled acetonitrile levels in a sample of 268 volunteers (48 smokers, 220 non-smokers) attending a local health fair. Breath specimens were collected into inert sample bags, with parallel collection of ambient air. Subsequently, all samples were analysed using proton transfer reaction-mass spectrometry (PTR-MS). Smokers had elevated levels of exhaled acetonitrile compared with non-smokers (p<0.001). Analysis using the receiver-operating-characteristic curve demonstrated that smoking can be predicted with a sensitivity of 79% and a specificity of 91%, using a cut-off concentration of 20.31 parts per billion of acetonitrile. This first field survey of exhaled acetonitrile in a large group of test persons demonstrates the feasibility of a rapid and non-invasive test for recent exposure to tobacco. We conclude that analysis of exhaled-breath acetonitrile may serve as a method of determining recent active smoking behaviour.

Для цитирования: Lirk Philipp, Bodrogi Florian, Deibl Martina, Kähler Christian M, Colvin Joshua, Moser Berthold, Pinggera Germar, Raifer Hartmann, Rieder Josef, Schobersberger Wolfgang. Quantification of recent smoking behaviour using proton transfer reaction-mass spectrometry (PTR-MS).. Wiener klinische Wochenschrift. 2004. DOI: 10.1007/bf03040419.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.