MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/15459624.2015.1072631

Медицинская библиотека · Journal of occupational and environmental hygiene · 2015

Temperature Measurement Inside Protective Headgear: Comparison With Core Temperatures and Indicators of Physiological Strain During Exercise in a Hot Environment.

Mitchell Joel B, Goldston Kelly R, Adams Amy N, Crisp Kelli M, Franklin Brian B, Kreutzer Andreas, Montalvo Diego X, Turner Marcell G, Phillips Melody D

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Non-invasive temperature monitoring with a sensor inside protective headgear may be effective in detecting temperatures that are associated with heat illness. The purpose was to establish the relationship between in-hardhat temperatures (Tih) and core temperature (Tc) as measured by rectal (Tre) and esophageal (Tes) probes. Thirty males (age 24.57 ± 4.32 yrs.) completed two trials: continuous submaximal exercise (CSE) and a series of high intensity 30-s sprints (HIE) with a one-minute rest between each. Exercise in both conditions was in a 36(°)C environment (40% RH) while wearing a standard hardhat with sensors mounted on the forehead that were monitored remotely. Exercise continued until voluntary termination or until Tc reached 39.5(°)C. Temperatures, heart rate, cardiorespiratory, and perceptual responses were monitored throughout. A physiological strain index (PSI) was calculated from Tc and HR. The final temperatures in the CSE condition were 38.77 ± 0.41, 38.90 ± 0.49 and 39.29 ± 0.58(°)C and in the HIE condition, final temperatures were 38.76 ± 0.37, 38.91 ± 0.47, and 39.19 ± 0.57 f (o)C for Tih, Tre, and Tes, respectively. The PSI in CSE was 9.62 ± 062, 9.18 ± 1.11, and 10.04 ± 1.05, and in the HIE condition 9.67 ± 068, 9.29 ± 0.99. and 9.86 ± 1.02 based on Tih, Tre and Tes, respectively. The general agreement between the Tih and other temperature measures along with the consistency as indicated by a low coefficient of variation (approx. 1%) in the recordings of the Tih sensors at the point of termination suggest that this device, or similar devices, may have application as a warning system for impending heat-related problems.

Для цитирования: Mitchell Joel B, Goldston Kelly R, Adams Amy N, Crisp Kelli M, Franklin Brian B, Kreutzer Andreas, Montalvo Diego X, Turner Marcell G, Phillips Melody D. Temperature Measurement Inside Protective Headgear: Comparison With Core Temperatures and Indicators of Physiological Strain During Exercise in a Hot Environment.. Journal of occupational and environmental hygiene. 2015. DOI: 10.1080/15459624.2015.1072631.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.