DOI 10.1016/j.prosdent.2014.04.029
Comparison of the accuracy of a 3-dimensional virtual method and the conventional method for transferring the maxillary cast to a virtual articulator.
Аннотация
STATEMENT OF PROBLEM: The currently available virtual articulators fail to locate the digitized maxillary cast at the exact position in the virtual environment. Some locate the casts on a mechanical articulator with a facebow, and this position is then digitized for the virtual environment.
PURPOSE: The purpose of this study was to compare the location of the maxillary cast on an articulator by using 2 different procedures: the conventional method and a virtual method.
MATERIAL AND
METHODS
With the conventional procedure, the kinematic axis of the participant was determined with an axiograph. The location of the maxillary cast in reference to this axis was then physically transferred to a Panadent mechanical articulator. By a virtual procedure, the same kinematic axis and the maxillary cast were transferred directly from the participant to the Panadent virtual articulator by means of reverse engineering devices. The locations obtained with both procedures were compared in a virtual environment with an optical scanner. By calculating the deviation at every point of the occlusal surface, the results obtained with this procedure were then compared with those of the conventional method.
RESULTS
The mean deviation on the occlusal surface was 0.752 mm, and the standard deviation was 0.456 mm.
CONCLUSIONS
The deviation between the procedures was sufficiently small to allow the methodology for orthodontic purposes. However, the accuracy of the virtual procedure should be improved so as to extend its use to other fields, such as orthognathic surgery or dental restorations, in which the clinical technique requires an articulator.