Molecules (Basel, Switzerland) · 2025

Therapeutic Drug Monitoring of Everolimus Using Volumetric Absorptive Microsampling and Quantitative Dried Blood Spot Methods with LC-MS/MS in Adult Solid Organ Transplant Recipients: An Analytical and Clinical Comparative Study.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kocur Arkadiusz, Olkowski Bartosz, Moczulski Mateusz, Miszewska-Szyszkowska Dorota, Rostkowska Olga Maria, Polak Katarzyna, Korniluk Katarzyna, Bączkowska Teresa, Durlik Magdalena, Pawiński Tomasz

Аннотация

Everolimus (EVE), an mTOR inhibitor, is widely used in solid organ transplantation (SOT) because of its immunosuppressive properties. Due to its narrow therapeutic window and significant pharmacokinetic variability, therapeutic drug monitoring (TDM) is essential for achieving optimal outcomes. We developed and thoroughly validated a robust LC-MS/MS method to measure EVE levels in venous whole blood (WB) and capillary blood collected using two microsampling devices: Mitra™ (volumetric absorptive microsampling, VAMS) and Capitainer® (quantitative dried blood spot, qDBS). The validation followed EMA and IATDMCT guidelines, assessing linearity (1.27-64.80 ng/mL for WB and 0.50-60 ng/mL for VAMS/qDBS), as well as selectivity, accuracy, precision, matrix effects, recovery, stability, and incurred sample reanalysis. Clinical validation involved 66 matched samples from 33 adult SOT recipients. The method demonstrated high accuracy and precision across all matrices, with no significant carryover or matrix interference. Statistical analysis using Passing-Bablok regression and Bland-Altman plots showed excellent agreement between the microsampling methods and the venous reference. Hematocrit effects were tested both in laboratory conditions and on clinical samples and were found to be negligible. This study provides the first comprehensive analytical and clinical validation of the Mitra and Capitainer devices for EVE monitoring. The validated LC-MS/MS microsampling method supports decentralized, patient-centred TDM, offering a reliable alternative to conventional blood sampling in transplant care.