DOI 10.1097/ftd.0000000000001248

Медицинская библиотека · Therapeutic drug monitoring · 2024

Limited Sampling Strategies Fail to Accurately Predict Mycophenolic Acid Area Under the Curve in Kidney Transplant Recipients and the Impact of Enterohepatic Recirculation.

Mohamed Moataz E, Saqr Abdelrahman, Al-Kofahi Mahmoud, Onyeaghala Guillaume, Remmel Rory P, Staley Christopher, Dorr Casey R, Teigen Levi, Guan Weihua, Madden Henry, Munoz Julia, Vo Duy, Sanchez Bryan, El-Rifai Rasha, Oetting William S, Matas Arthur J, Israni Ajay K, Jacobson Pamala A

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Therapeutic drug monitoring for mycophenolic acid (MPA) is challenging due to difficulties in measuring the area under the curve (AUC). Limited sampling strategies (LSSs) have been developed for MPA therapeutic drug monitoring but come with risk of unacceptable performance. The authors hypothesized that the poor predictive performance of LSSs were due to the variability in MPA enterohepatic recirculation (EHR). This study is the first to evaluate LSSs models performance in the context of EHR.

METHODS

Adult kidney transplant recipients (n = 84) receiving oral mycophenolate mofetil underwent intensive MPA pharmacokinetic sampling. MPA AUC 0-12hr and EHR were determined. Published MPA LSSs in kidney transplant recipients receiving tacrolimus were evaluated for their predictive performance in estimating AUC 0-12hr in our full cohort and separately in individuals with high and low EHR.

RESULTS

None of the evaluated LSS models (n = 12) showed good precision or accuracy in predicting MPA AUC 0-12hr in the full cohort. In the high EHR group, models with late timepoints had better accuracy but low precision, except for 1 model with late timepoints at 6 and 10 hours postdose, which had marginally acceptable precision. For all models, the good guess of predicted AUC 0-12hr (±15% of observed AUC 0-12hr ) was highly variable (range, full cohort = 19%-61.9%; high EHR = 4.5%-65.9%; low EHR = 27.5%-62.5%).

CONCLUSIONS

The predictive performance of the LSS models varied according to EHR status. Timepoints ≥5 hours postdose in LSS models are essential to capture EHR. Models and strategies that incorporate EHR during development are required to accurately ascertain MPA exposure.

Для цитирования: Mohamed Moataz E, Saqr Abdelrahman, Al-Kofahi Mahmoud, Onyeaghala Guillaume, Remmel Rory P, Staley Christopher, Dorr Casey R, Teigen Levi, Guan Weihua, Madden Henry, Munoz Julia, Vo Duy, Sanchez Bryan, El-Rifai Rasha, Oetting William S, Matas Arthur J, Israni Ajay K, Jacobson Pamala A. Limited Sampling Strategies Fail to Accurately Predict Mycophenolic Acid Area Under the Curve in Kidney Transplant Recipients and the Impact of Enterohepatic Recirculation.. Therapeutic drug monitoring. 2024. DOI: 10.1097/ftd.0000000000001248.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.