MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjopen-2023-075554

Медицинская библиотека · BMJ open · 2024

Feasibility of continuous glucose monitoring in patients with type 1 diabetes at two district hospitals in Neno, Malawi: a randomised controlled trial.

Gomber Apoorva, Valeta Francis, Coates Matthew M, Trujillo Celina, Ferrari Gina, Boti Medson, Kumwenda Kenwood, Mailosi Bright, Nakotwa Dester, Drown Laura, Wroe Emily B, Thapa Ada, Mithi Victor, Matanje Beatrice, Msekandiana Amos, Park Paul H, Kachimanga Chiyembekezo, Bukhman Gene, Ruderman Todd, Adler Alma J

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To assess the feasibility and change in clinical outcomes associated with continuous glucose monitoring (CGM) use among a rural population in Malawi living with type 1 diabetes.

DESIGN

A 2:1 open randomised controlled feasibility trial.

SETTING

Two Partners In Health-supported Ministry of Health-run first-level district hospitals in Neno, Malawi.

PARTICIPANTS

45 people living with type 1 diabetes (PLWT1D).

INTERVENTIONS: Participants were randomly assigned to Dexcom G6 CGM (n=30) use or usual care (UC) (n=15) consisting of Safe-Accu glucose monitors and strips. Both arms received diabetes education.

OUTCOMES: Primary outcomes included fidelity, appropriateness and severe adverse events. Secondary outcomes included change in haemoglobin A1c (HbA1c), acceptability, time in range (CGM arm only) SD of HbA1c and quality of life.

RESULTS

Participants tolerated CGM well but were unable to change their own sensors which resulted in increased clinic visits in the CGM arm. Despite the hot climate, skin rashes were uncommon but cut-out tape overpatches were needed to secure the sensors in place. Participants in the CGM arm had greater numbers of dose adjustments and lifestyle change suggestions than those in the UC arm. Participants in the CGM arm wore their CGM on average 63.8% of the time. Participants in the UC arm brought logbooks to clinic 75% of the time. There were three hospitalisations all in the CGM arm, but none were related to the intervention.

CONCLUSIONS

This is the first randomised controlled trial conducted on CGM in a rural region of a low-income country. CGM was feasible and appropriate among PLWT1D and providers, but inability of participants to change their own sensors is a challenge.

TRIAL REGISTRATION NUMBER: PACTR202102832069874.

Для цитирования: Gomber Apoorva, Valeta Francis, Coates Matthew M, Trujillo Celina, Ferrari Gina, Boti Medson, Kumwenda Kenwood, Mailosi Bright, Nakotwa Dester, Drown Laura, Wroe Emily B, Thapa Ada, Mithi Victor, Matanje Beatrice, Msekandiana Amos, Park Paul H, Kachimanga Chiyembekezo, Bukhman Gene, Ruderman Todd, Adler Alma J. Feasibility of continuous glucose monitoring in patients with type 1 diabetes at two district hospitals in Neno, Malawi: a randomised controlled trial.. BMJ open. 2024. DOI: 10.1136/bmjopen-2023-075554.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.