MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1248/yakushi.22-00182

Медицинская библиотека · Yakugaku zasshi : Journal of the Pharmaceutical Society of Japan · 2023

[Evaluation of Plasma Concentrations of Mycophenolic Acid in Renal Transplant Patients Using LM1010 High-performance Liquid Chromatography].

Akamine Yumiko, Matsushita Miyuki, Morikawa Satoru, Miura Masatomo

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

Plasma concentrations of mycophenolic acid (MPA), an immunosuppressive agent, have been measured in clinical settings using immunoassay methods or HPLC. However, immunoassay methods show cross-reactivity with metabolites of MPA glucuronide. Recently, the LM1010 high-performance liquid chromatography instrument was approved as a new general medical device. In this study, we compared the results of MPA plasma concentrations analyzed using the LM1010 method and the previously described HPLC method. Plasma samples obtained from 100 renal transplant patients (32 women and 68 men) were evaluated using both HPLC instruments. Deming regression analyses showed a very high correlation between the two instruments, with a slope of 0.9892 and an intercept of 0.0235 µg/mL (r2=0.982). Bland-Altman analysis showed an average of -0.0012 µg/mL between the LM1010 method and the previously described HPLC method. For the LM1010 method, the total run time for MPA analysis was 7 min, and the analytical time was short; however, the extraction recovery when using a spin column was extremely low for frozen plasma samples stored at -20°C for 1 month, and the volume required for the assay (150 µL) could not be collected. Thus, for the LM1010 method, analysis using fresh plasma samples was optimal. Overall, our findings showed that the LM1010 method was a rapid, accurate HPLC assay for MPA analysis and could be used in clinical practice for routine monitoring of MPA in fresh plasma samples.

Для цитирования: Akamine Yumiko, Matsushita Miyuki, Morikawa Satoru, Miura Masatomo. [Evaluation of Plasma Concentrations of Mycophenolic Acid in Renal Transplant Patients Using LM1010 High-performance Liquid Chromatography].. Yakugaku zasshi : Journal of the Pharmaceutical Society of Japan. 2023. DOI: 10.1248/yakushi.22-00182.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.