MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.13324

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2018

Day-case device implantation-A prospective single-center experience including patient satisfaction data.

Peplow Jessica, Randall Esther, Campbell-Cole Carolyn, Kamdar Ravi, Petzer Ed, Dhillon Para, Murgatroyd Francis, Scott Paul A

СтатьяПеревод в очереди

Аннотация

PURPOSE: Many centers perform day-case cardiac rhythm management (CRM) device implantation. However, there is a paucity of prospective data concerning this approach. We performed a prospective single-center study of day-case device implantation, including data on patient satisfaction.

METHODS

All patients scheduled for a new elective device were considered for a day-case procedure. Exclusion criteria were living alone or without a suitable carer, advancing age/frailty, a metallic valve, and persistent complete heart block. Following discharge, patients were reviewed in device clinic at 6 weeks with an anonymized questionnaire.

RESULTS

During the study period (May 2014-August 2016), 797 new CRM devices were implanted. Of these, 232 were elective and included in the analysis; 101 were planned to be day-case and 131 scheduled for overnight stay. Of the 101 day-case patients, 52 had a pacemaker, 28 an implantable cardioverter defibrillator (ICD), 16 a cardiac resynchronization therapy pacemaker/defibrillator, and five a subcutaneous-ICD. Complications were similar in the day-case (n  =  12, 12%) and overnight stay (n  =  15, 11%) groups (P  =  0.92). In the day-case group, 93 (92%) patients went home the same day. An estimated 111 overnight bed days were saved, translating to a cost saving of £61,912 (euro 70,767, $79,211). Note that 99% (n  =  100) of patients returned the questionnaire. Patient satisfaction was universally high. The majority (n  =  98, 98%) felt ready to go home on discharge; only a minority (n  =  5, 5%) would have preferred an overnight stay.

CONCLUSIONS

A significant proportion of elective new CRM device implants can be performed as day-case procedures. With appropriate selection patient acceptability of same-day discharge is high.

Для цитирования: Peplow Jessica, Randall Esther, Campbell-Cole Carolyn, Kamdar Ravi, Petzer Ed, Dhillon Para, Murgatroyd Francis, Scott Paul A. Day-case device implantation-A prospective single-center experience including patient satisfaction data.. Pacing and clinical electrophysiology : PACE. 2018. DOI: 10.1111/pace.13324.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.