MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d4ay00514g

Медицинская библиотека · Analytical methods : advancing methods and applications · 2024

Development of optical and electrochemical immunodevices for dengue virus detection.

Torres do Couto Milena Tereza, Galdino da Silva Júnior Alberto, Pereira Dos Santos Avelino Karen Yasmim, Vega Gonzales Gil Laura Helena, Cordeiro Marli Tenório, Lima de Oliveira Maria Danielly, Souza de Andrade César Augusto

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Dengue virus (DENV) is the most prevalent global arbovirus, exhibiting a high worldwide incidence with intensified severity of symptoms and alarming mortality rates. Faced with the limitations of diagnostic methods, an optical and electrochemical biosystem was developed for the detection of DENV genotypes 1 and 2, using cysteine (Cys), cadmium telluride (CdTe) quantum dots, and anti-DENV antibodies. Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), surface plasmon resonance (SPR), atomic force microscopy (AFM), and Fourier transform infrared spectroscopy (FTIR) were employed to characterize the immunosensor. The AFM and SPR results demonstrated discernible topographic and angular changes confirming the biomolecular recognition. Different concentrations of DENV-1 and DENV-2 were evaluated (0.05 × 106 to 2.0 × 106 PFU mL-1), resulting in a maximum anodic shift (ΔI%) of 263.67% ± 12.54 for DENV-1 and 63.36% ± 3.68 for DENV-2. The detection strategies exhibited a linear response to the increase in viral concentration. Excellent linear correlations, with R2 values of 0.95391 for DENV-1 and 0.97773 for DENV-2, were obtained across a broad concentration range. Data analysis demonstrated high reproducibility, displaying relative standard deviation values of 3.42% and 3.62% for Cys-CdTe-antibodyDENV-1-BSA and Cys-CdTe-antibodyDENV-2-BSA systems. The detection limits were 0.34 × 106 PFU mL-1 and 0.02 × 106 PFU mL-1, while the quantification limits were set at 1.49 × 106 PFU mL-1 and 0.06 × 106 PFU mL-1 for DENV-1 and DENV-2, respectively. Therefore, the biosensing apparatus demonstrates analytical effectiveness in viral screening and can be considered an innovative solution for early dengue diagnosis, contributing to global public health.

Для цитирования: Torres do Couto Milena Tereza, Galdino da Silva Júnior Alberto, Pereira Dos Santos Avelino Karen Yasmim, Vega Gonzales Gil Laura Helena, Cordeiro Marli Tenório, Lima de Oliveira Maria Danielly, Souza de Andrade César Augusto. Development of optical and electrochemical immunodevices for dengue virus detection.. Analytical methods : advancing methods and applications. 2024. DOI: 10.1039/d4ay00514g.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.