MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1166/jnn.2018.15446

Медицинская библиотека · Journal of nanoscience and nanotechnology · 2018

Size-Strain Analysis of Iron-Excess Mn-Zn Ferrite Nanoparticles Using Synchrotron Diffraction and Its Correlation with Magnetic Saturation and Isoelectric pH.

Ichikawa Rodrigo U, Parra João P R L L, Martins Murillo L, Yoshito Walter K, Saeki Margarida J, Turrillas Xavier, Martinez Luis G

СтатьяПеревод в очереди

Аннотация

Iron-excess Mn-Zn ferrite nanoparticles were prepared by coprecipitation with sodium hydroxide (NaOH) at different concentrations (0.1, 0.2, 0.5 and 1.0 mol/L). The results of X-ray diffraction (XRD) analysis using Whole Powder Pattern Modeling (WPPM) showed that higher concentrations of NaOH promote crystallite growth and broader dispersion in crystallite sizes. Energy dispersive X-ray spectroscopy indicates that zinc loss is noticeable when [NaOH] ≥ 0.2 mol/L. XRD revealed also a significant less-crystalline phase contribution alongside the main peaks of the nanocrystalline cubic spinel ferrite phase. The less-crystalline fraction is lower for the ferrite obtained with 0.2 mol/L of NaOH, being about 50% and more than 70% for the other samples. Despite of the less-crystalline fraction and the excess of iron, no secondary phases were detected. The Warren curves showed that the concentration of NaOH significantly influences the microstrain in the crystallites, being smaller for the sample obtained with NaOH at 0.2 mol/L. The sample prepared with this condition presented the better properties to be used as magnetic tracer in clinical diagnoses combining small mean crystallite size, low microstrain, which resulted in materials with higher magnetic saturation and high surface charge under blood pH.

Для цитирования: Ichikawa Rodrigo U, Parra João P R L L, Martins Murillo L, Yoshito Walter K, Saeki Margarida J, Turrillas Xavier, Martinez Luis G. Size-Strain Analysis of Iron-Excess Mn-Zn Ferrite Nanoparticles Using Synchrotron Diffraction and Its Correlation with Magnetic Saturation and Isoelectric pH.. Journal of nanoscience and nanotechnology. 2018. DOI: 10.1166/jnn.2018.15446.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.