MedElevator Войти в исследования
← Поиск публикаций

DOI 10.25259/sni_1101_2022

Медицинская библиотека · Surgical neurology international · 2023

Controversies and challenges of coil embolization for intracranial aneurysm in a continuous-flow LVAD implanted patient: A case report.

Sato Daisuke, Koizumi Satoshi, Umekawa Motoyuki, Kioyofuji Satoshi, Ando Masahiko, Ono Minoru, Saito Nobuhito

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Continuous-flow left ventricular assist device (CF-LVAD) technology has rapidly developed to support the failing heart refractory to standard medical treatments. Although the expected prognosis has improved dramatically, ischemic and hemorrhagic strokes are possible complications and the leading causes of death in the CF-LVAD population.

CASE DESCRIPTION: We encountered a case of an unruptured large internal carotid aneurysm in a patient with a CF-LVAD. Following a detailed discussion of his expected prognosis, the risk of aneurysm rupture, and the inherited risk of aneurysm treatment, coil embolization was performed without adverse events. The patient remained recurrence-free for 2-year postoperatively.

CONCLUSION

This report illustrates the feasibility of coil embolization in a CF-LVAD recipient and emphasizes the necessity of vigilant consideration of whether to intervene in an intracranial aneurysm after CF-LVAD implantation. We confronted several challenges during the treatment: optimal endovascular technique, management of antithrombotic drugs, safe arterial access, desirable perioperative imaging modalities, and prevention of ischemic complications. This study aimed to share this experience.

Для цитирования: Sato Daisuke, Koizumi Satoshi, Umekawa Motoyuki, Kioyofuji Satoshi, Ando Masahiko, Ono Minoru, Saito Nobuhito. Controversies and challenges of coil embolization for intracranial aneurysm in a continuous-flow LVAD implanted patient: A case report.. Surgical neurology international. 2023. DOI: 10.25259/sni_1101_2022.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.