MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.thromres.2021.05.021

Медицинская библиотека · Thrombosis research · 2021

Electrical impedance vs. light transmission aggregometry: Testing platelet reactivity to antiplatelet drugs using the MICELI POC impedance aggregometer as compared to a commercial predecessor.

Mencarini Tatiana, Roka-Moiia Yana, Bozzi Silvia, Redaelli Alberto, Slepian Marvin J

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Patients' responses to antiplatelet therapy significantly vary, with individuals showing high residual platelet reactivity associated with thrombosis. To personalize thrombosis management, platelet function testing has been suggested as a promising tool able to monitor the antithrombotic effect of antiplatelet agents in real-time. We have prototyped the MICELI, a miniature and easy-to-use electrical impedance aggregometer (EIA), measuring platelet aggregation in whole blood. Here, we tested the capability of the MICELI aggregometer to quantify platelet reactivity on antiplatelet agents, as compared with conventional light-transmission aggregometry (LTA).

METHODS

Platelet aggregation in ACD-anticoagulated whole blood and platelet-rich plasma of healthy donors (n = 30) was evaluated. The effect of clopidogrel, ticagrelor, cangrelor, cilostazol, and tirofiban on ADP-induced aggregation was tested, while aspirin was evaluated with arachidonic acid and collagen. Platelet aggregation was recorded using the MICELI or BioData PAP-8E (Bio/Data Corp.) aggregometers.

RESULTS

The MICELI aggregometer detected an adequate and comparable dose-dependent decrease of platelet aggregation in response to increments of drugs' concentrations, as compared to LTA (the inter-device R2 = 0.79-0.93). Platelet aggregation in platelet-rich plasma recorded by LTA showed higher sensitivity to antiplatelet agents, but it couldn't distinguish between different drug doses as indicated by saturation of the aggregatory response.

CONCLUSION

Platelet aggregation in whole blood as recorded by EIA represents a better model system for evaluation of platelet reactivity as compared with platelet aggregation in platelet-rich plasma as recorded by LTA, since EIA takes into consideration the modulatory effect of other blood cells on platelet hemostatic function and pharmacodynamics of antiplatelet drugs in vivo. As such, the MICELI impedance aggregometer could be potentially employed for the point-of-care monitoring of platelet function in patients on-treatment for personalized tailoring of their antiplatelet regimen.

Для цитирования: Mencarini Tatiana, Roka-Moiia Yana, Bozzi Silvia, Redaelli Alberto, Slepian Marvin J. Electrical impedance vs. light transmission aggregometry: Testing platelet reactivity to antiplatelet drugs using the MICELI POC impedance aggregometer as compared to a commercial predecessor.. Thrombosis research. 2021. DOI: 10.1016/j.thromres.2021.05.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.