MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00604-023-06109-y

Медицинская библиотека · Mikrochimica acta · 2023

A functionalized Sup35NM nanofibril-assisted oriented antibody capture in lateral flow immunoassay for sensitive detection of dengue type II NS1.

Qin Ting, Wu Peidian, Zhang Qiankun, Kang Keren, Ma Yi, Wang Jufang

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Rapid and sensitive dengue non-structural protein 1 (NS1) detection assay is essential for the treatment of disease and currently releases high medical cost burdens. To address the limitations of conventional LFIA strips, we have developed an improved Sup35NM-Z-based LFIA that immobilizes antibodies on cellulose membranes in an orientated manner to increase the sensitivity of LFIA strips. A dual-functional Sup35NM nanofibril was fabricated by fusion with the antibody binding domain; resultant nanofibril from the amyloid Sup35NM was sprayed on the T-line to orientate the capture antibody and produces fluorescence signals. Antibody binding analysis showed that self-assembly of the Sup35NM monomer does not affect the binding activity of the Z-domain with the antibody. The NS1 for DENV-2 infection was chosen as a model target antigen to assess the feasibility of the Sup35NM-Z-domain-based LFIA platform. Under optimal conditions, the Sup35NM-Z-domain-based LFIA detected NS1 within 15 min with a detection limit of 1.29 ng/ml, while the detection limit of traditional LFIA with the same concentration of anti-NS1-Ab1 on the T-line by conventional physical adsorption was 2.20 ng/ml, 1.7 times higher than that of Sup35NM-Z-domain-based LFIA. As compared to traditional LFIAs, the Sup35NM-Z-based LFIA had a wide detection range of 1.29-625 ng/mL. The LFIA's clinical performance in identifying NS1 was also assessed using 15 clinical samples. The LFIA accurately recognized positive and negative samples, equal to 86.7% accuracy. The developed Sup35NM-Z-domain-based LFIA in this study offers great potential for the identification of target markers because of its greatly improved sensitivity and wider detection range.

Для цитирования: Qin Ting, Wu Peidian, Zhang Qiankun, Kang Keren, Ma Yi, Wang Jufang. A functionalized Sup35NM nanofibril-assisted oriented antibody capture in lateral flow immunoassay for sensitive detection of dengue type II NS1.. Mikrochimica acta. 2023. DOI: 10.1007/s00604-023-06109-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.