m+Medelevator.RU
← Поиск публикаций
Circulation · 2004

Elevated troponin T levels and lesion characteristics in non-ST-elevation acute coronary syndromes.

Клиническое исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Okamatsu Kentaro, Takano Masamichi, Sakai Shunta, Ishibashi Fumiyuki, Uemura Ryota, Takano Teruo, Mizuno Kyoichi

Аннотация

BACKGROUND: Elevated troponin T levels in non-ST-elevation acute coronary syndromes (NSTE-ACS) have been shown to predict an adverse outcome. Furthermore, it has been reported that troponin T could help improve the effectiveness of such new antithrombotic drugs as platelet GPIIb/IIIa antagonists and low-molecular-weight heparins. We hypothesized that such elevated troponin T levels in NSTE-ACS indicate the presence of thrombus at culprit lesions, and this hypothesis was verified through the use of coronary angioscopy.

METHODS AND RESULTS: We studied 57 consecutive patients with NSTE-ACS who underwent preinterventional angioscopy. Before catheterization, we obtained blood samples to determine troponin positivity, and the patients were then classified as either troponin-positive or troponin-negative groups (diagnostic threshold, 0.1 ng/mL). Using angioscopy at the culprit lesions, we examined the presence of coronary thrombus, yellow plaque, and complex plaque. Moreover, we compared the preinterventional angiographic parameters (thrombus and complexity of the culprit lesion, and TIMI flow) between the two groups. Twenty-two patients were troponin-positive and 35 patients were troponin-negative. Univariate analyses indicated that the TIMI flow and the incidence of coronary thrombus detected with angioscopy correlate with the elevated troponin T levels. A multivariate logistic regression analysis showed the presence of coronary thrombus detected with angioscopy to be the only independent factor associated with elevated troponin T levels in patients with NSTE-ACS (odds ratio, 22.1; 95% CI, 2.59 to 188.42; P=0.0046).

CONCLUSIONS: Using angioscopy, the elevated troponin T levels in NSTE-ACS were confirmed to be strongly associated with the presence of coronary thrombus.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты