MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/bf01833985

Медицинская библиотека · International journal of cardiac imaging · 1990

Arterial stenting with self-expandable and balloon-expandable endoprostheses.

van der Giessen W J, Serruys P W, van Woerkens L J, Beatt K J, Visser W J, Jongkind J F, van Bremen R H, Ridderhof E, van Loon H, Soei L K

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Coronary angioplasty is complicated by acute occlusion (within 24 hours) and late restenosis (within 6 months) in 2-5% and 20-40% of the cases, respectively. Vascular endoprostheses (stents) may provide the cardiologist with a solution to some of these complications. Several stent-devices are now available for experimental and clinical evaluation. In this study we describe our experience with two metallic stents in normal arteries of swine. Self-expandable, stainless steel stents (3.5 mm diameter) were implanted in 17 peripheral arteries, eight of which were deendothelialized by prior balloon angioplasty. Following implantation, the animals received antithrombotic therapy with acenocoumarol and aspirin (8 stents), or aspirin alone (9 stents). After 1 week repeat angiography was performed, which showed patency of all stented arteries. Microscopy showed complete covering by neointima, 80 microns in thickness. This self-expandable stent (SES) and a balloon-expandable stent (BES), constructed of tantalum, were implanted in normal coronary arteries. SES (3.0 and 3.5 mm) receiving animals were treated with coumadines (10 stents) or received no antithrombotic treatment (16 stents) after implantation. BES receiving animals were also not treated (10 stents). Three untreated animals with SES died suddenly within 48 hours. Postmortem examination showed partial or complete thrombosis of all six stents in these animals, resulting in a patency rate of 62% after 1 week. All animals with SES, which were treated with coumadines, and all animals with BES (untreated) had patent stents after one week. It is concluded that SES implanted in normal coronary arteries of pigs, which do not receive additional antithrombotic treatment, show a 38% occlusion rate within 48 hours, but show 100% patency after 1 week, when the animals are treated with coumadines. BES implanted in normal coronary arteries of pigs, which do not receive antithrombotic drugs, are 100% patent after 1 week.

Для цитирования: van der Giessen W J, Serruys P W, van Woerkens L J, Beatt K J, Visser W J, Jongkind J F, van Bremen R H, Ridderhof E, van Loon H, Soei L K. Arterial stenting with self-expandable and balloon-expandable endoprostheses.. International journal of cardiac imaging. 1990. DOI: 10.1007/bf01833985.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.