MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/0002-9149(94)90330-1

Медицинская библиотека · The American journal of cardiology · 1994

Differences in clot lysis among patients demonstrated in vitro with three thrombolytic agents (tissue-type plasminogen activator, streptokinase and urokinase).

Musselman D R, Tate D A, Oberhardt B J, Abruzzini A F, Blauwet M B, Koch G, Dehmer G J

Сравнительное исследованиеСтатьяПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

This study compares the ability of 3 thrombolytic drugs to promote clot lysis using a new in vitro testing procedure. Whole blood samples from 132 patients were tested using 5 different concentrations of tissue-type plasminogen activator (t-PA), streptokinase (SK) and urokinase. A mixture of blood and thrombolytic drug was placed on a dry-reagent test card containing reptilase, buffers and paramagnetic particles where clot formation occurred. Analysis of the motion of the clot-embedded paramagnetic particles caused by an oscillating magnetic field was used to define the lysis onset time. The slope of the linear regression plot of lysis onset time versus 1/[drug concentration] defined the kinetic rate constant (k) for each drug in each patient. Higher values of k indicated greater resistance to in vitro clot lysis. In the patients studied, there was a large range of k values for t-PA and SK (coefficient of variation 143 and 137%, respectively) but a smaller range of k for urokinase (coefficient of variation 32%). The coefficients of variation for t-PA and SK observed in the study group were five- to 10-fold greater than the coefficients of variation determined for replicate test measurements. Resistance to all SK concentrations tested was found in 9% of the patients. In vitro sensitivity to thrombolysis was compared among the drugs by correlating the derived k values. These comparisons indicated no relation for any of the drugs; many patients had a relatively low k value for 1 drug, while having a relatively high k value for a different drug.(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Musselman D R, Tate D A, Oberhardt B J, Abruzzini A F, Blauwet M B, Koch G, Dehmer G J. Differences in clot lysis among patients demonstrated in vitro with three thrombolytic agents (tissue-type plasminogen activator, streptokinase and urokinase).. The American journal of cardiology. 1994. DOI: 10.1016/0002-9149(94)90330-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.