MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.6c02170

Медицинская библиотека · Analytical chemistry · 2026

Research on the FAIMS System Based on Multijet DBD Ion Source and Background Noise Suppression.

Du Xiaoxia, Wang Shuanglong, Wu Yi, Xu Zhengyi, Li Yao, Shi Yankun, Li Hua

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

This study designs and constructs a dielectric barrier discharge (DBD)-field asymmetric ion mobility spectrometry (FAIMS) system. An innovative approach is adopted to fabricate a multi-channel DBD ion source using 3D printing technology. The printing material itself served as the discharge medium, enabling the simultaneous generation of four plasma jets, effectively enhancing the ionization efficiency. By optimizing the inlet positions of nitrogen and helium gases, the background ion signal intensity was reduced from 356.3 pA to 0, effectively eliminating the system background noise. Under the optimal working conditions, namely when the four-stream ion source operates at a helium gas flow rate of 0.5 L/min, a discharge voltage of -5.1 kV, and a nitrogen gas flow rate of 1.2 L/min, the detection sensitivity of FAIMS was significantly improved compared to the single-stream source. The nonlinear coefficient α curve characteristics of the FAIMS spectrum were utilized to distinguish different samples. As a validation of the application prospect, exhaled gas samples from diabetic patients and healthy volunteers were collected and analyzed. The results showed that the characteristic signal intensity of acetone in the exhaled gas of diabetic patients was higher than that of healthy controls, and when the blood glucose level was 2.5 mmol/L higher, the signal intensity was approximately 0.25 times higher. This preliminary study proves the potential of this system in non-invasive screening of diabetes.

Для цитирования: Du Xiaoxia, Wang Shuanglong, Wu Yi, Xu Zhengyi, Li Yao, Shi Yankun, Li Hua. Research on the FAIMS System Based on Multijet DBD Ion Source and Background Noise Suppression.. Analytical chemistry. 2026. DOI: 10.1021/acs.analchem.6c02170.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.