Analytical chemistry · 2026

Dual-Target Immunosensor Based on SERS for Simultaneous Sensing of Hemoglobin and Glycated Hemoglobin in Human Whole Blood.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Jiang Hao, Xu Shanshan, Fu Shi-Ying, Huang Yinxiang, Kuang Tingting, Lin Jia-Sheng, Zhang Yue-Jiao, Liu Changqin, Li Jian-Feng

Аннотация

Glycated hemoglobin (HbA1c) refers to the product of the nonenzymatic reaction of hemoglobin (Hb) with glucose and is clinically routine for assessing long-term glycemic control by monitoring its proportion relative to total Hb. However, exclusive reliance on the absolute amount of HbA1c may misjudge patients' glycemic status; moreover, current commercial detection methods are constrained by the need for specialized equipment/operators or high per-test costs. These two limitations underscore the urgency to develop rapid, portable, and low-cost point-of-care testing (POCT) strategies. Herein, we propose a novel dual-target surface-enhanced Raman scattering (SERS) biosensor based on a magnetic bead-assisted sandwich immunoassay for the simultaneous detection of HbA1c and Hb. Target biomarkers in highly diluted whole blood are specifically captured by antibody-modified magnetic beads, enabling rapid enrichment and complex matrix separation. Subsequently, silica-coated gold nanoparticles (Au@SiO2) embedded with IR-808 and NBA reporters bind to the captured targets, forming a stable sandwich structure. Meanwhile, a 785 nm laser (near-infrared region) was selected to avoid fluorescence interference from the biological matrix and minimize fluorescence-induced spectral overlap, thereby improving detection sensitivity. Notably, the developed method exhibited a favorable linear correlation (R2 = 0.979) with clinical high-performance liquid chromatography (HPLC) measurements, confirming its reliability. It further enables direct, simultaneous quantitative detection of HbA1c and Hb in human whole blood with minimal sample preprocessing, supporting a more accurate evaluation of HbA1c levels. Furthermore, the method requires <10 μL sample volume and involves a simple one-step mixing procedure, which not only enhances patient comfort but also demonstrates significant potential for future POCT applications.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты