MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00216-026-06648-2

Медицинская библиотека · Analytical and bioanalytical chemistry · 2026

A label-free membrane-based biosensor array with AuNP-modified PDMS for sensitive and specific detection of alpha-fetoprotein.

Zhao Zhongfu, Zhao Dong, Wang Haoyu, Yu Xingbo, Wu Sitong, Ma Jianan, Guo Xing, Ji Jianlong, Zhou Chuangang, Sang Shengbo

СтатьяПеревод в очереди

Аннотация

The surface stress-based transduction enabled by antibody functionalization has emerged as a promising paradigm for label-free biosensor development. However, the inherent limitations of conventional detection methods (e.g., high cost, complex modification, insufficient sensitivity) and the challenge of achieving high-throughput analysis hinder their practical clinical application. Herein, a high-throughput label-free biosensor array based on multi-component integration of gold nanoparticles (AuNPs), polydimethylsiloxane (PDMS) membrane, and conductive silver paste is proposed for sensitive and specific detection of alpha-fetoprotein (AFP), a pivotal biomarker for hepatocellular carcinoma (HCC). The specific immunoreaction between immobilized anti-AFP antibodies and target AFP induces compressive surface stress, which triggers PDMS membrane deformation and regulates the electrical resistance of the AuNP conductive layer, realizing the stress-electric coupling transduction. Systematic optimization of antibody surface density (50 μg/mL) and AuNP layer thickness (0.67 μm) maximizes antigen capture efficiency and mechano-electrical transduction performance. The proof-of-concept application for AFP detection demonstrates remarkable analytical performance: a linear detection range of 0-50 ng/mL, a low limit of detection (LOD) of 0.225 ng/mL, high specificity against interfering biomolecules. Furthermore, accurate detection of AFP in clinical serum samples (relative error < 5.05%, RSD < 2.97%) confirms its practical applicability. All these results indicate that the integrated design and parameter optimization of the AuNP-PDMS-based biosensor array enhance the performance of surface stress biosensors, providing a cost-effective platform for the sensitive detection of clinical cancer biomarkers.

Для цитирования: Zhao Zhongfu, Zhao Dong, Wang Haoyu, Yu Xingbo, Wu Sitong, Ma Jianan, Guo Xing, Ji Jianlong, Zhou Chuangang, Sang Shengbo. A label-free membrane-based biosensor array with AuNP-modified PDMS for sensitive and specific detection of alpha-fetoprotein.. Analytical and bioanalytical chemistry. 2026. DOI: 10.1007/s00216-026-06648-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.