MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/smll.74265

Медицинская библиотека · Small (Weinheim an der Bergstrasse, Germany) · 2026

Interface-Encoded Dynamic Covalent Crosslinking Enables Ultra-Stretchable, Signal-Stable Conductive Elastomers.

Liu Qing, Yu Jie, Peng Meihong, Li Yizhen, Dou Yonghui, Shen Yi, Yu Enze, Li Ping, Yao Xinwei, Liu Shanqiu

СтатьяПеревод в очереди

Аннотация

Conductive composite elastomers for soft electronics are often constrained by a fundamental trade-off: weak filler-matrix adhesion leads to interfacial defects, stress concentration, and signal instability under dynamic strain, whereas conventional covalent "locking" improves adhesion at the cost of elasticity and stretchability. Here, we report a dynamic covalent interface engineering strategy that resolves this conflict by converting the filler-matrix boundary into a reconfigurable, stress-dissipative covalent junction. Lipoic-acid-functionalized carbon nanofibers (CNFs) serve as nanoscale multi-point crosslinkers within a polylipoic-acid-based elastomer, where surface-grafted 1,2-dithiolane rings undergo reversible disulfide exchange with the matrix to strengthen stress transfer while preserving network mobility. The resulting bio-based conductive elastomers exhibit ultra-stretchability (∼4200%) with markedly enhanced toughness and up to three- to fivefold higher conductivity compared with unmodified-CNF controls. They operate over an exceptionally wide sensing range (0%-3000% strain), delivering gauge factors up to 8.13 and ∼2× higher ΔR/R0 amplitudes, together with highly reproducible, low-hysteresis responses under repeated large-strain deformation. DFT calculations support the interfacial mechanism by revealing strengthened disulfide-mediated binding. Enabled by the same dynamic chemistry, the elastomers further show room-temperature self-healing and closed-loop recyclability. This work establishes an interface-encoded molecular design principle for ultra-stretchable, electromechanically stable, and sustainable conductive elastomers.

Для цитирования: Liu Qing, Yu Jie, Peng Meihong, Li Yizhen, Dou Yonghui, Shen Yi, Yu Enze, Li Ping, Yao Xinwei, Liu Shanqiu. Interface-Encoded Dynamic Covalent Crosslinking Enables Ultra-Stretchable, Signal-Stable Conductive Elastomers.. Small (Weinheim an der Bergstrasse, Germany). 2026. DOI: 10.1002/smll.74265.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.