DOI 10.1016/j.jviromet.2025.115260

Медицинская библиотека · Journal of virological methods · 2025

A dual-target real-time PCR for proactive detection of Mpox variants.

Lee Tracy D, O'Dwyer Alan, Chan Michael, Cheung Branco, Tsang Frankie, Tyson John R, Kolehmainen Kathleen L, Prystajecky Natalie A, Jassem Agatha N

СтатьяПеревод в очереди

Аннотация

In 2022, cases of Monkeypox virus (MPXV) in California contained a mutation in the TNF receptor gene (GR2G) that rendered the virus undetectable using a widely adopted public health diagnostic qPCR assay. This underscored the need for a dual-target PCR approach and prompted validation of a second target by the BCCDC Public Health Laboratory. In addition to the GR2G target validated in the original qPCR assay (and duplexed with the endogenous target human β-globin (HBG)), GP113 (OPG128) was identified and validated using both clinical samples and MPXV DNA controls. Mutations in GR2G and GP113 (found in the emerging clade Ib) were also addressed along with the updated target. The new triplex assay (GR2G/GP113/HBG) had 100 % inclusivity and 100 % accuracy with all clinical samples tested and did not cross-react with herpes simplex virus-1 or -2, varicella zoster virus, or enterovirus. It showed < 5 % coefficient of variance between replicates and had a limit-of-detection of 10 copies/μL for GR2G and GP113. The use of two targets presents redundancy against further mutations in MPXV and is recommended for use with all viral qPCR assays moving forward.

Для цитирования: Lee Tracy D, O'Dwyer Alan, Chan Michael, Cheung Branco, Tsang Frankie, Tyson John R, Kolehmainen Kathleen L, Prystajecky Natalie A, Jassem Agatha N. A dual-target real-time PCR for proactive detection of Mpox variants.. Journal of virological methods. 2025. DOI: 10.1016/j.jviromet.2025.115260.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.