MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00216-025-06287-z

Медицинская библиотека · Analytical and bioanalytical chemistry · 2025

Comparative evaluation of immunoaffinity and antibody-free isotope dilution mass spectrometry approaches for plasma ProGRP quantification.

Li Jiahui, Yao Huan, Zhang Qiaoxuan, Yan Yuqi, Cui Xinling, Huang Xianzhang, Xing Wenjing, Ju Huanyu, Song Dewei, Xiao Peng, Ma Jian

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

Isotope dilution mass spectrometry (IDMS) is a critical technique for the quantification of protein biomarkers in complex biological samples, enabling sensitive measurement through integration with sample preparation to eliminate matrix interference. Nevertheless, the interchangeability between distinct pretreatment strategies is poorly defined. Herein, two traceable IDMS methods, immune mass spectrometry (IMS) and direct mass spectrometry (DMS), that combine immunoaffinity or antibody-free pretreatment were established for the quantification of plasma ProGRP, which is a recognized biomarker for small cell lung cancer. The internal standard curve was established using NLLGLIEAK, an enzymatic hydrolysis peptide of ProGRP, and its isotope-labeled molecule to ensure quantitative traceability. A microliter high-performance liquid chromatography tandem mass spectrometry platform was established for sensitive quantification of ProGRP in the range of 0.398-13.8 ng/mL. Correction factors were introduced to eliminate the effects of protein loss and enzyme digestion efficiency on the quantitative results, which were 86.84% for IMS and 85.48% for DMS. The RSDs of IMS and DMS were 5.5% and 4.3%, respectively. The comparability among the established MS methods and two immune methods was studied using plasma from patients with abnormally high expression of ProGRP. The IMS and DMS results showed good consistency and good correlation with the results of clinical chemiluminescent immunoassay (CLIA), while the correlation between CLIA and enzyme-linked immunosorbent assay (ELISA) results was poor. The factors affecting quantification accuracy by MS analysis and immunoassay were discussed, revealing the potential of IMS and DMS as reference measurement procedures for protein biomarkers in complex matrices.

Для цитирования: Li Jiahui, Yao Huan, Zhang Qiaoxuan, Yan Yuqi, Cui Xinling, Huang Xianzhang, Xing Wenjing, Ju Huanyu, Song Dewei, Xiao Peng, Ma Jian. Comparative evaluation of immunoaffinity and antibody-free isotope dilution mass spectrometry approaches for plasma ProGRP quantification.. Analytical and bioanalytical chemistry. 2025. DOI: 10.1007/s00216-025-06287-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.