DOI 10.1007/s12325-025-03326-0
Evaluation of Glycemia Risk Index and Continuous Glucose Monitoring Outcomes Following the Transition to an Advanced Hybrid Closed-Loop System in Type 1 Diabetes.
Аннотация
INTRODUCTION
Advanced hybrid closed-loop (AHCL) systems have shown promise in improving glycemic control in adults with type 1 diabetes (T1D), yet real-world evidence remains limited. This study evaluated the impact of transitioning from multiple daily injections (MDI) or conventional continuous subcutaneous insulin infusion (CSII) to the Tandem t:slim X2™ Control-IQ® AHCL system on glycemic outcomes in adults with T1D.
METHODS
In this retrospective study, 56 non-pregnant adults with T1D were followed for 6 months. Primary outcomes were changes in the Glycemia Risk Index (GRI) and percentage time in the tight range (%TiTR70-140). Secondary outcomes included other standardized ambulatory glucose profile metrics as well as additional glycemic, anthropometric, and insulin dosing measures.
RESULTS
Transition to the Control-IQ system increased %TiTR70-140 by 11.5 percentage points and reduced GRI by 23.5 points. Both components of the GRI, hypoglycemia risk (%Chypo) and hyperglycemia risk (%Chyper), improved significantly. Hemoglobin A1c decreased by 1.0%, time in range (%TIR70-180) improved by 13.6 percentage points, and glycemic variability (CV%) showed marked improvement. Total daily insulin dose decreased by 34%, accompanied by modest weight loss. No diabetic ketoacidosis episodes were reported throughout the study period.
CONCLUSION
Transitioning to the Tandem t:slim X2 Control-IQ AHCL system led to significant improvements in tight glycemic control, glycemic risk reduction, and insulin efficiency, with a favorable safety profile. These findings support broader adoption of AHCL technology and underscore the need for prospective multicenter studies.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало