European journal of nuclear medicine and molecular imaging · 2025
Histopathologic outcomes of hepatocellular carcinoma treated with transarterial radioembolization with yttrium-90 resin microspheres.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Sarwar Ammar, Nasser Imad, Weinstein Jeffrey L, Odeh Mahmoud, Babar Hafsa, Dinh Diana, Curry Michael, Bullock Andrea, Eckhoff Devin, Dib Martin, Parker John A, Ahmed Muneeb
Аннотация
PURPOSE: To evaluate the pathologic outcomes of 90Y-TARE of HCC with resin microspheres prescribed using the single-compartment model and to correlate posttreatment dose with outcomes.
METHODS: This retrospective single-center study included adult patients with HCC who underwent 90Y-TARE with resin microspheres before liver transplantation or surgery. Histopathologic evaluation of liver tissue was performed. Complete pathologic necrosis (CPN) was defined as 100% tumor necrosis, extensive necrosis as 50-99%, and partial necrosis as < 50%. Posttreatment voxel-based dosimetry was conducted. Additional subgroup analysis was done to compare tumors with complete and incomplete necrosis.
RESULTS: Among 28 patients (median age, 64 years [IQR, 57-69 years]); 86% males,75% BCLC 0-A) with 37 HCC tumors, complete, extensive and partial pathologic necrosis were achieved in 27/37(73%), 8/37(22%) and 2/37(5%) tumors, respectively. Tumors with CPN were significantly smaller than those without CPN (2.2 vs. 3.4 cm, P = 0.03), with longer interval between the 90Y-TARE and liver surgery (274 vs. 143 days, P = 0.048). All tumors with a mean tumor absorbed dose ≥ 433 Gy had CPN. Conversely, all tumors in which 4% or more of the tumor volume received a dose less than 100 Gy had incomplete necrosis. ROC analysis identified D95 ≥ 133 Gy (AUC 0.96 [95%CI: 0.9-1]) and V0-100 (%) < 5% (AUC 0.9 [95%CI: 0.75-0.97]) as predictors of CPN with 100% and 78% specificity, respectively.
CONCLUSION: Among HCC patients who underwent 90Y-TARE with resin microspheres, 73% achieved complete pathologic necrosis. All tumors with a mean tumor absorbed dose ≥ 433 Gy achieved CPN.
CLINICAL TRIAL NUMBER: not applicable.
METHODS: This retrospective single-center study included adult patients with HCC who underwent 90Y-TARE with resin microspheres before liver transplantation or surgery. Histopathologic evaluation of liver tissue was performed. Complete pathologic necrosis (CPN) was defined as 100% tumor necrosis, extensive necrosis as 50-99%, and partial necrosis as < 50%. Posttreatment voxel-based dosimetry was conducted. Additional subgroup analysis was done to compare tumors with complete and incomplete necrosis.
RESULTS: Among 28 patients (median age, 64 years [IQR, 57-69 years]); 86% males,75% BCLC 0-A) with 37 HCC tumors, complete, extensive and partial pathologic necrosis were achieved in 27/37(73%), 8/37(22%) and 2/37(5%) tumors, respectively. Tumors with CPN were significantly smaller than those without CPN (2.2 vs. 3.4 cm, P = 0.03), with longer interval between the 90Y-TARE and liver surgery (274 vs. 143 days, P = 0.048). All tumors with a mean tumor absorbed dose ≥ 433 Gy had CPN. Conversely, all tumors in which 4% or more of the tumor volume received a dose less than 100 Gy had incomplete necrosis. ROC analysis identified D95 ≥ 133 Gy (AUC 0.96 [95%CI: 0.9-1]) and V0-100 (%) < 5% (AUC 0.9 [95%CI: 0.75-0.97]) as predictors of CPN with 100% and 78% specificity, respectively.
CONCLUSION: Among HCC patients who underwent 90Y-TARE with resin microspheres, 73% achieved complete pathologic necrosis. All tumors with a mean tumor absorbed dose ≥ 433 Gy achieved CPN.
CLINICAL TRIAL NUMBER: not applicable.