MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2025.117468

Медицинская библиотека · Biosensors & bioelectronics · 2025

Cascaded logic gate-based electrochemical analysis of multiple miRNAs for cancer recognition.

Ma Ding, Wang Yaojun, Xu Yi, Chen Chang, Mi Xianqiang

СтатьяПеревод в очереди

Аннотация

Current miRNA detection methods mainly focus on the detection of discrete targets while overlooking the logical relationship among biomoleculars. Integrating electrochemical sensor, DNA framework probes and DNA logic gate technology for analyzing miRNAs with diverse combinations in bodily fluids provide a potential way for recognition of multiple cancers. In this work, a novel cascaded logic gate-based electrochemical (EC) analysis strategy was designed and fabricated for the discrimination of pancreatic cancer (PC), breast cancer (BC) and lung cancer (LC). Cascaded AND logic gates were constructed through the logical relationship among miR-21, miR-155, miR-373, miR-6746 and miR-1343 which abnormally expressed in PC, BC and LC. The output strands of the logic gates were captured by tetrahedral DNA framework probes modified on the electrodes of EC sensor. Three cascaded AND logic gates successfully achieved limits of detection (LOD) of 0.62 nM, 0.37 nM and 0.41 nM, and good linear relationships between current values and the concentration of miRNA combinations within the range from 1 nM to 1 μM (R2 > 0.99). It was shown that multiple cascaded logic gate-based EC method could distinguish PC, BC and LC through specific miRNA combinations both in a TM buffer and in a 50 % fetal bovine serum samples. This logic gate-based EC method has the advantages of precision, high speed and logical analysis capability which provides a brand-new tool for system and precision medicine.

Для цитирования: Ma Ding, Wang Yaojun, Xu Yi, Chen Chang, Mi Xianqiang. Cascaded logic gate-based electrochemical analysis of multiple miRNAs for cancer recognition.. Biosensors & bioelectronics. 2025. DOI: 10.1016/j.bios.2025.117468.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.