MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/20552076241277746

Медицинская библиотека · Digital health · 2024

Solving variability: Accurately extracting feature components from ballistocardiograms.

Yang Tianyi, Yuan Haihang, Yang Junqi, Zhou Zhongchao, Abe Masayuki, Nakayama Yoshitake, Huang Shao Ying, Yu Wenwei

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

A ballistocardiogram (BCG) is a vibration signal generated by the ejection of the blood in each cardiac cycle. The BCG has significant variability in amplitude, temporal aspects, and the deficiency of waveform components, attributed to individual differences, instantaneous heart rate, and the posture of the person being measured. This variability may make methods of extracting J-waves, the most distinct components of BCG less generalizable so that the J-waves could not be precisely localized, and further analysis is difficult. This study is dedicated to solving the variability of BCG to achieve accurate feature extraction.

METHODS

Inspired by the generation mechanism of the BCG, we proposed an original method based on a profile of second-order derivative of BCG waveform (2ndD-P) to capture the nature of vibration and solve the variability, thereby accurately localizing the components especially when the J-wave is not prominent.

RESULTS

In this study, 51 recordings of resting state and 11 recordings of high-heart-rate from 24 participants were used to validate the algorithm. Each recording lasts about 3 min. For resting state data, the sensitivity and positive predictivity of proposed method are: 98.29% and 98.64%, respectively. For high-heart-rate data, the proposed method achieved a performance comparable to those of low-heart-rate: 97.14% and 99.01% for sensitivity and positive predictivity, respectively.

CONCLUSION

Our proposed method can detect the peaks of the J-wave more accurately than conventional extraction methods, under the presence of different types of variability. Higher performance was achieved for BCG with non-prominent J-waves, in both low- and high-heart-rate cases.

Для цитирования: Yang Tianyi, Yuan Haihang, Yang Junqi, Zhou Zhongchao, Abe Masayuki, Nakayama Yoshitake, Huang Shao Ying, Yu Wenwei. Solving variability: Accurately extracting feature components from ballistocardiograms.. Digital health. 2024. DOI: 10.1177/20552076241277746.