MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0000000000001778

Медицинская библиотека · Cornea · 2019

Precut DMEK Using Dextran-Containing Storage Medium Is Equivalent to Conventional DMEK: A Prospective Pilot Study.

Rickmann Annekatrin, Wahl Silke, Hofmann Nicola, Haus Arno, Michaelis Regina, Petrich Tanja, Blomberg Lutz, Börgel Martin, Jung Sascha, Szurman Peter

СтатьяПеревод в очереди

Аннотация

PURPOSE: To compare the clinical outcome after Descemet membrane endothelial keratoplasty (DMEK) either as precut or conventional Descemet membrane graft preparation under standard European eye bank organ culture conditions.

METHODS

This was a prospective pilot study of patients receiving either precut or conventional DMEK. Graft preparation was performed using the liquid bubble technique. Precut grafts (n = 22) were prepared 1 day before surgery in the eye bank and stored in dextran-containing organ culture medium within a transport viewing chamber. Conventional grafts (n = 29) were prepared directly before surgery. End point criteria included the endothelial cell count (ECC), central corneal thickness, graft rejection rate, rebubbling rate, and best-corrected visual acuity after 1, 3, and 6 months.

RESULTS

A post hoc matched analysis revealed no statistically significant differences between the 2 groups. The ECC in the precut and conventional groups was comparable with an EC loss of 34% and 35%, respectively, after 6 months. The early graft failure rate, best-corrected visual acuity, and central corneal thickness were comparable between the 2 groups.

CONCLUSIONS

This pilot study shows a comparable clinical outcome after DMEK surgery for precut Descemet membrane grafts versus conventionally prepared grafts, using the liquid bubble preparation technique and storage conditions with dextran-containing medium.

Для цитирования: Rickmann Annekatrin, Wahl Silke, Hofmann Nicola, Haus Arno, Michaelis Regina, Petrich Tanja, Blomberg Lutz, Börgel Martin, Jung Sascha, Szurman Peter. Precut DMEK Using Dextran-Containing Storage Medium Is Equivalent to Conventional DMEK: A Prospective Pilot Study.. Cornea. 2019. DOI: 10.1097/ico.0000000000001778.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.