MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jclinane.2017.12.022

Медицинская библиотека · Journal of clinical anesthesia · 2018

A mini-fluid challenge of 150mL predicts fluid responsiveness using ModelflowR pulse contour cardiac output directly after cardiac surgery.

Smorenberg Annemieke, Cherpanath Thomas G V, Geerts Bart F, de Wilde Robert B P, Jansen Jos R C, Maas Jacinta J, Groeneveld A B Johan

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

STUDY

OBJECTIVE

The mini-fluid challenge may predict fluid responsiveness with minimum risk of fluid overloading. However, the amount of fluid as well as the best manner to evaluate the effect is unclear. In this prospective observational pilot study, the value of changes in pulse contour cardiac output (CO) measurements during mini-fluid challenges is investigated.

DESIGN

Prospective observational study.

SETTING

Intensive Care Unit of a university hospital.

PATIENTS: Twenty-one patients directly after elective cardiac surgery on mechanical ventilation.

INTERVENTIONS: The patients were subsequently given 10 intravenous boluses of 50mL of hydroxyethyl starch with a total of 500mL per patient while measuring pulse contour CO.

MEASUREMENTS: We measured CO by minimal invasive ModelflowR (COm) and PulseCOR (COli), before and one minute after each fluid bolus. We analyzed the smallest volume that was predictive of fluid responsiveness. A positive fluid response was defined as an increase in CO of >10% after 500mL fluid infusion.

MAIN

RESULTS

Fifteen patients (71%) were COm responders and 13 patients (62%) COli responders. An increase in COm after 150mL of fluid >5.0% yielded a positive and negative predictive value (+PV and -PV) of 100% with an area under the curve (AUC) of 1.00 (P<0.001). An increase in COli >6.3% after 200mL was able to predict a fluid response in COli after 500mL with a +PV of 100% and -PV of 73%, with an AUC of 0.88 (P<0.001).

CONCLUSION

The use of minimal invasive ModelflowR pulse contour CO measurements following a mini-fluid challenge of 150mL can predict fluid responsiveness and may help to improve fluid management.

Для цитирования: Smorenberg Annemieke, Cherpanath Thomas G V, Geerts Bart F, de Wilde Robert B P, Jansen Jos R C, Maas Jacinta J, Groeneveld A B Johan. A mini-fluid challenge of 150mL predicts fluid responsiveness using ModelflowR pulse contour cardiac output directly after cardiac surgery.. Journal of clinical anesthesia. 2018. DOI: 10.1016/j.jclinane.2017.12.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.