m+Medelevator.RU
← Поиск публикаций
Journal of anesthesia · 2017

Hydroxyethyl starch 130/0.4 versus crystalloid co-loading during general anesthesia induction: a randomized controlled trial.

Сравнительное исследованиеСтатьяРандомизированное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Juri Takashi, Suehiro Koichi, Kuwata Shigemune, Tsujimoto Sayaka, Mukai Akira, Tanaka Katsuaki, Yamada Tokuhiro, Mori Takashi, Nishikawa Kiyonobu

Аннотация

PURPOSE: Hypotension and decreased cardiac output (CO) are common adverse effects during anesthesia induction depending on the patient's pre-anesthetic cardiac condition. The aim of this study was to assess the ability of hydroxyethyl starch (HES) 130/0.4 to prevent hypotension and decreased CO during the induction of general anesthesia.

METHODS: Ninety patients undergoing laparoscopic surgery were randomly divided into a HES group and a crystalloid group. Following the insertion of an intravenous line, fluid was administered to each patient at a rate of 25 ml/min using either crystalloid or HES 130/0.4. Five minutes after the initiation of fluid loading, anesthesia was induced using propofol (1.5 mg/kg), rocuronium (0.9 mg/kg), and remifentanil (0.3 mcg/kg/min). Tracheal intubation was performed 5 min after the induction of anesthesia. Following tracheal intubation, general anesthesia was maintained using remifentanil and sevoflurane. Non-invasive blood pressure (BP) level was measured at 1-min intervals and CO was measured continuously using electrical cardiometry from the start of fluid loading until 5 min after tracheal intubation.

RESULTS: The number of patients with hypotension (systolic BP < 90 mmHg or 80% of baseline) was significantly lower in the HES group (p < 0.001) than in the crystalloid group. Patients in the HES group showed smaller CO decreases than did patients in the crystalloid group (p < 0.001). The Kaplan-Meier method showed a lower incidence and significantly slower onset of hypotension in the HES group (p = 0.009). Multivariate logistic regression models indicated that the use of HES is an independent factor for the prevention of both hypotension and decreased CO (below 85% of baseline; p < 0.005 for both).

CONCLUSIONS: Co-loading using HES 130/0.4 prevented hypotension and decreased CO during general anesthesia induction.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты